All pastes #984005 Raw Edit

Untitled

public text v1 · immutable
·published 2008-04-13 20:46 UTC
rendered paste body
=== START OF INFORMATION SECTION ===
Model Family:     SAMSUNG SpinPoint P80 series
Device Model:     SAMSUNG SP1614N
Serial Number:    S016J10Y904568
Firmware Version: TM100-30
User Capacity:    160.041.885.696 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 0
Local Time is:    Sun Apr 13 22:46:13 2008 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (  25) The self-test routine was aborted by
                                        the host.
Total time to complete Offline
data collection:                 (6000) seconds.
Offline data collection
capabilities:                    (0x1b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 100) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   100   100   051    Pre-fail  Always       -       0
  3 Spin_Up_Time            0x0007   100   100   025    Pre-fail  Always       -       5568
  4 Start_Stop_Count        0x0032   098   098   000    Old_age   Always       -       2300
  5 Reallocated_Sector_Ct   0x0033   100   100   011    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   100   100   051    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0025   100   100   015    Pre-fail  Offline      -       0
  9 Power_On_Half_Minutes   0x0032   099   099   000    Old_age   Always       -       8177h+42m
 10 Spin_Retry_Count        0x0033   100   100   051    Pre-fail  Always       -       0
 11 Calibration_Retry_Count 0x0012   100   100   000    Old_age   Always       -       1
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       1424
194 Temperature_Celsius     0x0022   148   115   000    Old_age   Always       -       30
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       -       4024560
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x000a   100   100   051    Old_age   Always       -       0
201 Soft_Read_Error_Rate    0x000a   100   100   051    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 940 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 940 occurred at disk power-on lifetime: 278 hours (11 days + 14 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 00 01 4f c2 b0  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  b0 d9 00 01 4f c2 b0 00      00:00:53.125  SMART DISABLE OPERATIONS
  ec 00 ff 01 00 00 b0 00      00:00:53.125  IDENTIFY DEVICE
  10 00 ff 01 00 00 b0 00      00:00:53.125  RECALIBRATE [OBS-4]
  91 00 ff 01 00 00 bf 00      00:00:53.125  INITIALIZE DEVICE PARAMETERS [OBS-6]
  ec 00 ff 01 00 00 b0 00      00:00:53.063  IDENTIFY DEVICE

Error 939 occurred at disk power-on lifetime: 278 hours (11 days + 14 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 00 01 4f c2 b0  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  b0 d9 00 01 4f c2 b0 00      00:00:24.875  SMART DISABLE OPERATIONS
  ec 00 ff 01 00 00 b0 00      00:00:24.875  IDENTIFY DEVICE
  10 00 ff 01 00 00 b0 00      00:00:24.875  RECALIBRATE [OBS-4]
  91 00 ff 01 00 00 bf 00      00:00:24.875  INITIALIZE DEVICE PARAMETERS [OBS-6]
  ec 00 ff 01 00 00 b0 00      00:00:24.813  IDENTIFY DEVICE

Error 938 occurred at disk power-on lifetime: 278 hours (11 days + 14 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 00 01 4f c2 b0  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  b0 d9 00 01 4f c2 b0 00      00:02:02.250  SMART DISABLE OPERATIONS
  ec 00 ff 01 00 00 b0 00      00:02:02.250  IDENTIFY DEVICE
  10 00 ff 01 00 00 b0 00      00:02:02.250  RECALIBRATE [OBS-4]
  91 00 ff 01 00 00 bf 00      00:02:02.250  INITIALIZE DEVICE PARAMETERS [OBS-6]
  ec 00 ff 01 00 00 b0 00      00:02:02.250  IDENTIFY DEVICE

Error 937 occurred at disk power-on lifetime: 278 hours (11 days + 14 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 00 01 4f c2 b0  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  b0 d9 00 01 4f c2 b0 00      00:01:11.688  SMART DISABLE OPERATIONS
  ec 00 ff 01 00 00 b0 00      00:01:11.688  IDENTIFY DEVICE
  10 00 ff 01 00 00 b0 00      00:01:11.688  RECALIBRATE [OBS-4]
  91 00 ff 01 00 00 bf 00      00:01:11.688  INITIALIZE DEVICE PARAMETERS [OBS-6]
  ec 00 ff 01 00 00 b0 00      00:01:11.688  IDENTIFY DEVICE

Error 936 occurred at disk power-on lifetime: 278 hours (11 days + 14 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  04 51 00 01 4f c2 b0  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  b0 d9 00 01 4f c2 b0 00      00:00:26.563  SMART DISABLE OPERATIONS
  ec 00 ff 01 00 00 b0 00      00:00:26.563  IDENTIFY DEVICE
  10 00 ff 01 00 00 b0 00      00:00:26.563  RECALIBRATE [OBS-4]
  91 00 ff 01 00 00 bf 00      00:00:26.563  INITIALIZE DEVICE PARAMETERS [OBS-6]
  ec 00 ff 01 00 00 b0 00      00:00:25.000  IDENTIFY DEVICE

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Abort offline test  Aborted by host               90%      7542         -

Device does not support Selective Self Tests/Logging