All pastes #975214 Raw Edit

Stuff

public text v1 · immutable
·published 2008-04-07 11:39 UTC
rendered paste body
[root@localhost ~]# smartctl  --all  /dev/hdd
smartctl version 5.36 [x86_64-redhat-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     ST3250824A
Serial Number:    4ND2KCJE
Firmware Version: 3.AAE
User Capacity:    250�059�350�016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Mon Apr  7 14:37:20 2008 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 ( 430) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 100) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   117   088   006    Pre-fail  Always       -       145375841
  3 Spin_Up_Time            0x0003   100   097   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       388
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   087   060   030    Pre-fail  Always       -       483702204
  9 Power_On_Hours          0x0032   090   090   000    Old_age   Always       -       9272
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       518
187 Unknown_Attribute       0x0032   098   098   000    Old_age   Always       -       2
189 Unknown_Attribute       0x003a   100   100   000    Old_age   Always       -       0
190 Unknown_Attribute       0x0022   072   051   045    Old_age   Always       -       471334940
194 Temperature_Celsius     0x0022   028   049   000    Old_age   Always       -       28 (Lifetime Min/Max 0/13)
195 Hardware_ECC_Recovered  0x001a   075   049   000    Old_age   Always       -       7931680
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   193   000    Old_age   Always       -       7
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline      -       0
202 TA_Increase_Count       0x0032   100   253   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 31 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 31 occurred at disk power-on lifetime: 9265 hours (386 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 a3 7b 04 4a e0  Error: UNC 163 sectors at LBA = 0x004a047b = 4850811

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 a3 7b 04 4a e0 00      00:00:53.238  READ DMA EXT
  25 00 a4 7a 04 4a e0 00      00:01:18.202  READ DMA EXT
  25 00 a5 79 04 4a e0 00      00:01:16.414  READ DMA EXT
  25 00 a6 78 04 4a e0 00      00:01:14.634  READ DMA EXT
  25 00 a7 77 04 4a e0 00      00:01:12.846  READ DMA EXT

Error 30 occurred at disk power-on lifetime: 9265 hours (386 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 7b 04 4a e0  Error: UNC at LBA = 0x004a047b = 4850811

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 a4 7a 04 4a e0 00      00:00:53.238  READ DMA EXT
  25 00 a5 79 04 4a e0 00      00:00:51.459  READ DMA EXT
  25 00 a6 78 04 4a e0 00      00:01:16.414  READ DMA EXT
  25 00 a7 77 04 4a e0 00      00:01:14.634  READ DMA EXT
  25 00 a8 76 04 4a e0 00      00:01:12.846  READ DMA EXT

Error 29 occurred at disk power-on lifetime: 9265 hours (386 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 7b 04 4a e0  Error: UNC at LBA = 0x004a047b = 4850811

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 a5 79 04 4a e0 00      00:00:53.238  READ DMA EXT
  25 00 a6 78 04 4a e0 00      00:00:51.459  READ DMA EXT
  25 00 a7 77 04 4a e0 00      00:00:49.671  READ DMA EXT
  25 00 a8 76 04 4a e0 00      00:01:14.634  READ DMA EXT
  25 00 a9 75 04 4a e0 00      00:01:12.846  READ DMA EXT

Error 28 occurred at disk power-on lifetime: 9265 hours (386 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 7b 04 4a e0  Error: UNC at LBA = 0x004a047b = 4850811

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 a6 78 04 4a e0 00      00:00:53.238  READ DMA EXT
  25 00 a7 77 04 4a e0 00      00:00:51.459  READ DMA EXT
  25 00 a8 76 04 4a e0 00      00:00:49.671  READ DMA EXT
  25 00 a9 75 04 4a e0 00      00:00:47.892  READ DMA EXT
  25 00 aa 74 04 4a e0 00      00:01:12.846  READ DMA EXT

Error 27 occurred at disk power-on lifetime: 9265 hours (386 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 7b 04 4a e0  Error: UNC at LBA = 0x004a047b = 4850811

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 a7 77 04 4a e0 00      00:00:53.238  READ DMA EXT
  25 00 a8 76 04 4a e0 00      00:00:51.459  READ DMA EXT
  25 00 a9 75 04 4a e0 00      00:00:49.671  READ DMA EXT
  25 00 aa 74 04 4a e0 00      00:00:47.892  READ DMA EXT
  25 00 ab 73 04 4a e0 00      00:00:46.112  READ DMA EXT

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.