All pastes #955932 Raw Edit

Miscellany

public text v1 · immutable
#955932 ·published 2008-03-24 22:40 UTC
rendered paste body
SDA
===
=== START OF INFORMATION SECTION ===
Model Family:     Western Digital Caviar RE Serial ATA series
Device Model:     WDC WD4000YR-01PLB0
Serial Number:    WD-WMAMY1569851
Firmware Version: 01.06A01
User Capacity:    400,088,457,216 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 published, ANSI INCITS 397-2005
Local Time is:    Mon Mar 24 18:34:24 2008 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84) Offline data collection activity
                                        was suspended by an interrupting command from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 (10530) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 152) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   200   200   051    Pre-fail  Always       -       0
  3 Spin_Up_Time            0x0007   222   222   021    Pre-fail  Always       -       5925
  4 Start_Stop_Count        0x0032   100   100   040    Old_age   Always       -       28
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000b   200   200   051    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0032   086   086   000    Old_age   Always       -       10383
 10 Spin_Retry_Count        0x0013   100   253   051    Pre-fail  Always       -       0
 11 Calibration_Retry_Count 0x0013   100   253   051    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       28
194 Temperature_Celsius     0x0022   125   120   000    Old_age   Always       -       27
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0012   200   200   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0012   200   200   000    Old_age   Always       -       0
199 UDMA_CRC_Error_Count    0x000a   200   253   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0009   200   200   051    Pre-fail  Offline      -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Conveyance offline  Completed without error       00%        66         -



SDD
===
=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.10 family
Device Model:     ST3750640AS
Serial Number:    5QD0CYFH
Firmware Version: 3.AAK
User Capacity:    750,156,374,016 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   7
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Mon Mar 24 18:40:23 2008 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 430) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off supp
ort.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 202) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   089   085   006    Pre-fail  Always       -       232009739
  3 Spin_Up_Time            0x0003   093   093   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       8
  5 Reallocated_Sector_Ct   0x0033   098   098   036    Pre-fail  Always       -       91
  7 Seek_Error_Rate         0x000f   084   060   030    Pre-fail  Always       -       259511910
  9 Power_On_Hours          0x0032   094   094   000    Old_age   Always       -       5587
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       5
187 Unknown_Attribute       0x0032   046   046   000    Old_age   Always       -       54
189 Unknown_Attribute       0x003a   100   100   000    Old_age   Always       -       0
190 Temperature_Celsius     0x0022   072   057   045    Old_age   Always       -       521338908
194 Temperature_Celsius     0x0022   028   043   000    Old_age   Always       -       28 (Lifetime Min/Max 0/19)
195 Hardware_ECC_Recovered  0x001a   061   048   000    Old_age   Always       -       84739387
197 Current_Pending_Sector  0x0012   059   059   000    Old_age   Always       -       841
198 Offline_Uncorrectable   0x0010   059   059   000    Old_age   Offline      -       841
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline      -       0
202 TA_Increase_Count       0x0032   100   253   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 54 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 54 occurred at disk power-on lifetime: 5586 hours (232 days + 18 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 37 8d b1 e0  Error: UNC at LBA = 0x00b18d37 = 11636023

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 37 8d b1 e0 00      04:53:22.257  READ DMA EXT
  27 00 00 00 00 00 e0 00      04:53:22.251  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 02      04:53:20.307  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 02      04:53:20.246  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      04:53:20.242  READ NATIVE MAX ADDRESS EXT

Error 53 occurred at disk power-on lifetime: 5586 hours (232 days + 18 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 37 8d b1 e0  Error: UNC at LBA = 0x00b18d37 = 11636023

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 37 8d b1 e0 00      04:53:22.257  READ DMA EXT
  27 00 00 00 00 00 e0 00      04:53:22.251  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 02      04:53:20.307  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 02      04:53:20.246  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      04:53:20.242  READ NATIVE MAX ADDRESS EXT

Error 52 occurred at disk power-on lifetime: 5586 hours (232 days + 18 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 37 8d b1 e0  Error: UNC at LBA = 0x00b18d37 = 11636023

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 37 8d b1 e0 00      04:53:16.067  READ DMA EXT
  27 00 00 00 00 00 e0 00      04:53:16.062  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 02      04:53:20.307  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 02      04:53:20.246  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      04:53:20.242  READ NATIVE MAX ADDRESS EXT

Error 51 occurred at disk power-on lifetime: 5586 hours (232 days + 18 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 37 8d b1 e0  Error: UNC at LBA = 0x00b18d37 = 11636023

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 37 8d b1 e0 00      04:53:16.067  READ DMA EXT
  27 00 00 00 00 00 e0 00      04:53:16.062  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 02      04:53:16.052  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 02      04:53:15.991  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      04:53:15.985  READ NATIVE MAX ADDRESS EXT

Error 50 occurred at disk power-on lifetime: 5586 hours (232 days + 18 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 37 8d b1 e0  Error: UNC at LBA = 0x00b18d37 = 11636023

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 37 8d b1 e0 00      04:53:16.067  READ DMA EXT
  27 00 00 00 00 00 e0 00      04:53:16.062  READ NATIVE MAX ADDRESS EXT
  ec 00 00 00 00 00 a0 02      04:53:16.052  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 02      04:53:15.991  SET FEATURES [Set transfer mode]
  27 00 00 00 00 00 e0 00      04:53:15.985  READ NATIVE MAX ADDRESS EXT

SMART Self-test log structure revision number 1

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.