All pastes #916235 Raw Edit

Someone

public text v1 · immutable
#916235 ·published 2008-02-24 13:38 UTC
rendered paste body
=== START OF INFORMATION SECTION ===
Model Family:     Fujitsu MHT series
Device Model:     FUJITSU MHT2030AT
Serial Number:    NN32T4416AJ1
Firmware Version: 849B
User Capacity:    30,005,821,440 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   6
ATA Standard is:  ATA/ATAPI-6 T13 1410D revision 3a
Local Time is:    Sun Feb 24 13:34:47 2008 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 220) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  30) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   100   100   046    Pre-fail  Always       -       43606
  2 Throughput_Performance  0x0005   100   100   030    Pre-fail  Offline      -       12386304
  3 Spin_Up_Time            0x0003   100   100   025    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   099   099   000    Old_age   Always       -       4684
  5 Reallocated_Sector_Ct   0x0033   100   100   024    Pre-fail  Always       -       8568460083208
  7 Seek_Error_Rate         0x000f   100   100   047    Pre-fail  Always       -       3499
  8 Seek_Time_Performance   0x0005   100   100   019    Pre-fail  Offline      -       0
  9 Power_On_Seconds        0x0032   055   055   000    Old_age   Always       -       22585h+11m+54s
 10 Spin_Retry_Count        0x0013   100   100   020    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       2010
192 Power-Off_Retract_Count 0x0032   099   099   000    Old_age   Always       -       391
193 Load_Cycle_Count        0x0032   076   076   000    Old_age   Always       -       242556
194 Temperature_Celsius     0x0022   100   080   000    Old_age   Always       -       42 (Lifetime Min/Max 14/64)
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       -       75
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       81891360776
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       1
198 Offline_Uncorrectable   0x0010   099   099   000    Old_age   Offline      -       3
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x000f   100   068   060    Pre-fail  Always       -       24131
203 Run_Out_Cancel          0x0002   100   100   000    Old_age   Always       -       1533288120709

SMART Error Log Version: 1
ATA Error Count: 1325 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1325 occurred at disk power-on lifetime: 22399 hours (933 days + 7 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 59 21 6e 01 30 e0  Error: UNC at LBA = 0x0030016e = 3146094

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c4 ff 21 6e 01 30 e0 00      00:38:03.532  READ MULTIPLE
  c8 ff 21 6e 01 30 e0 00      00:37:58.535  READ DMA
  ef 03 45 ff ff 00 e0 00      00:37:58.511  SET FEATURES [Set transfer mode]
  ef 03 0c ff ff 00 e0 00      00:37:58.509  SET FEATURES [Set transfer mode]
  c6 ff 10 ff ff 00 e0 00      00:37:58.509  SET MULTIPLE MODE

Error 1324 occurred at disk power-on lifetime: 22399 hours (933 days + 7 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 59 16 79 01 30 e0  Error: UNC 22 sectors at LBA = 0x00300179 = 3146105

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 ff 21 6e 01 30 e0 00      00:37:58.535  READ DMA
  ef 03 45 ff ff 00 e0 00      00:37:58.511  SET FEATURES [Set transfer mode]
  ef 03 0c ff ff 00 e0 00      00:37:58.509  SET FEATURES [Set transfer mode]
  c6 ff 10 ff ff 00 e0 00      00:37:58.509  SET MULTIPLE MODE
  10 ff 50 3f 6b b1 e0 00      00:37:58.506  RECALIBRATE [OBS-4]

Error 1323 occurred at disk power-on lifetime: 22399 hours (933 days + 7 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 59 21 6e 01 30 e0  Error: UNC at LBA = 0x0030016e = 3146094

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c4 ff 21 6e 01 30 e0 00      00:37:53.483  READ MULTIPLE
  c8 ff 21 6e 01 30 e0 00      00:37:48.497  READ DMA
  c8 ff 1f 4f 01 30 e0 00      00:37:48.485  READ DMA
  ef 03 45 ff ff 00 e0 00      00:37:48.461  SET FEATURES [Set transfer mode]
  ef 03 0c ff ff 00 e0 00      00:37:48.459  SET FEATURES [Set transfer mode]

Error 1322 occurred at disk power-on lifetime: 22399 hours (933 days + 7 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 59 16 79 01 30 e0  Error: UNC 22 sectors at LBA = 0x00300179 = 3146105

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 ff 21 6e 01 30 e0 00      00:37:48.497  READ DMA
  c8 ff 1f 4f 01 30 e0 00      00:37:48.485  READ DMA
  ef 03 45 ff ff 00 e0 00      00:37:48.461  SET FEATURES [Set transfer mode]
  ef 03 0c ff ff 00 e0 00      00:37:48.459  SET FEATURES [Set transfer mode]
  c6 ff 10 ff ff 00 e0 00      00:37:48.459  SET MULTIPLE MODE

Error 1321 occurred at disk power-on lifetime: 22399 hours (933 days + 7 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 59 21 6e 01 30 e0  Error: UNC at LBA = 0x0030016e = 3146094

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c4 ff 21 6e 01 30 e0 00      00:37:43.433  READ MULTIPLE
  c8 ff 21 6e 01 30 e0 00      00:37:38.313  READ DMA
  ef 03 45 ff ff 00 e0 00      00:37:38.284  SET FEATURES [Set transfer mode]
  ef 03 0c ff ff 00 e0 00      00:37:38.283  SET FEATURES [Set transfer mode]
  c6 ff 10 ff ff 00 e0 00      00:37:38.282  SET MULTIPLE MODE

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.