rendered paste body# zaptel.conf
loadzone=us
defaultzone=us
#Sangoma A102 port 1 [slot:4 bus:24 span: 1]
span=1,0,0,esf,b8zs
e&m=1-24
#Sangoma A102 port 2 [slot:4 bus:24 span: 2]
span=2,0,0,esf,b8zs
fxoks=25-48
#Sangoma A102 port 1 [slot:4 bus:20 span: 3]
span=3,0,0,esf,b8zs
fxoks=49-72
#Sangoma A200 [slot:4 bus:15 span:4]
fxsks=73
fxsks=74
fxsks=75
fxsks=76
# zapata.conf
[channels]
; Sangoma A102-1 port 1 (channels 1-24) (T1 to Telco)
context=from-external
transfer=no
threewaycalling=no
usecallerid=no
group=1
signalling=em_w
channel => 1-24
; Sangoma A102-2 port 2 (channels 25-48) (T1 to Rhino CB24-FXS)
context=from-internal
transfer=yes
threewaycalling=no
usecallerid=yes
group=2
signalling=fxo_ks
channel => 25-48
; Sangoma A102-2 port 1 (channels 49-72) (T1 to Adit stations)
context=from-internal
transfer=yes
threewaycalling=yes
usecallerid=yes
group=3
signalling=fxo_ks
channel => 49-72
; Sangoma A200 ports 1-4 (channels 73-76) (inbound DID/outbound TF/outbound 911
context=from-external
transfer=no
threewaycalling=no
usecallerid=yes
busydetect=yes
group=4
signalling=fxs_ks
channel => 73-76