rendered paste bodysmartctl -a /dev/hdb
smartctl version 5.33 [i686-pc-linux-gnu] Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
Warning! Drive Identity Structure error: invalid SMART checksum.
=== START OF INFORMATION SECTION ===
Device Model: ST320414A
Serial Number: 3EC0SK7K
Firmware Version: 3.28
User Capacity: 20,003,618,816 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 4
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Wed Feb 13 15:28:02 2008 EET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
Warning! SMART Attribute Data Structure error: invalid SMART checksum.
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 121) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: ( 422) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 17) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000e 073 057 025 Old_age Always - 207492871
3 Spin_Up_Time 0x0002 083 070 000 Old_age Always - 0
4 Start_Stop_Count 0x0032 099 099 020 Old_age Always - 1111
5 Reallocated_Sector_Ct 0x0032 100 100 036 Old_age Always - 0
7 Seek_Error_Rate 0x000e 082 060 030 Old_age Always - 170190129
9 Power_On_Hours 0x0032 093 093 000 Old_age Always - 6163
10 Spin_Retry_Count 0x0012 100 100 097 Old_age Always - 0
12 Power_Cycle_Count 0x0032 099 099 020 Old_age Always - 1638
194 Temperature_Celsius 0x0022 036 060 000 Old_age Always - 36
195 Hardware_ECC_Recovered 0x001a 070 058 000 Old_age Always - 107922735
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 1
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 1
199 UDMA_CRC_Error_Count 0x003e 072 179 000 Old_age Always - 77
200 Multi_Zone_Error_Rate 0x0000 100 100 000 Old_age Offline - 0
202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 165 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 165 occurred at disk power-on lifetime: 6163 hours (256 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 00 00 00 f0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
48 00 20 00 00 00 f0 00 00:04:24.509 [RESERVED]
48 00 20 00 00 00 f0 00 00:04:23.853 [RESERVED]
10 00 3f 00 00 00 f0 00 00:04:23.851 RECALIBRATE [OBS-4]
48 00 20 00 00 00 f0 00 00:04:23.208 [RESERVED]
48 00 20 00 00 00 f0 00 00:04:22.545 [RESERVED]
Error 164 occurred at disk power-on lifetime: 6163 hours (256 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 00 00 00 f0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
48 00 20 00 00 00 f0 00 00:04:23.853 [RESERVED]
10 00 3f 00 00 00 f0 00 00:04:23.851 RECALIBRATE [OBS-4]
48 00 20 00 00 00 f0 00 00:04:23.208 [RESERVED]
48 00 20 00 00 00 f0 00 00:04:22.545 [RESERVED]
46 00 10 00 00 00 f0 00 00:04:22.545 [RESERVED]
Error 163 occurred at disk power-on lifetime: 6163 hours (256 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 00 00 00 f0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
48 00 20 00 00 00 f0 00 00:04:23.208 [RESERVED]
48 00 20 00 00 00 f0 00 00:04:22.545 [RESERVED]
46 00 10 00 00 00 f0 00 00:04:22.545 [RESERVED]
10 00 3f 00 00 00 f0 00 00:04:22.544 RECALIBRATE [OBS-4]
11 00 3f 3f ff 3f ff 00 00:04:22.544 RECALIBRATE [RET-4]
Error 162 occurred at disk power-on lifetime: 6163 hours (256 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 00 00 00 f0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
48 00 20 00 00 00 f0 00 00:04:22.545 [RESERVED]
46 00 10 00 00 00 f0 00 00:04:22.545 [RESERVED]
10 00 3f 00 00 00 f0 00 00:04:22.544 RECALIBRATE [OBS-4]
11 00 3f 3f ff 3f ff 00 00:04:22.544 RECALIBRATE [RET-4]
00 00 00 00 00 00 00 06 00:04:22.506 NOP [Abort queued commands]
Error 161 occurred at disk power-on lifetime: 6163 hours (256 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 00 00 00 f0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
48 00 20 00 00 00 f0 00 00:03:49.260 [RESERVED]
48 00 20 00 00 00 f0 00 00:03:48.581 [RESERVED]
10 00 3f 00 00 00 f0 00 00:03:48.581 RECALIBRATE [OBS-4]
48 00 20 00 00 00 f0 00 00:03:48.122 [RESERVED]
48 00 20 00 00 00 f0 00 00:03:47.660 [RESERVED]
Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed: read failure 90% 6163 1503825
Device does not support Selective Self Tests/Logging