-- File Name : OCCAM-MLT-MIB
-- Date : Tues Apr 17 11:00:00 MST 2007
-- Author : Steve Kittleson
OCCAM-MLT-MIB DEFINITIONS ::= BEGIN
IMPORTS
occamGenericMonitorModules
FROM OCCAM-REG-MODULE
TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY
FROM SNMPv2-SMI;
occamMltMib MODULE-IDENTITY
LAST-UPDATED "200702220000Z"
ORGANIZATION "Occam Networks"
CONTACT-INFO "email support@occamnetworks.com"
DESCRIPTION
"This mib module describes objects used to perform
Metallic Line Testing on customer access lines
and to provide results."
REVISION "200704170000Z"
DESCRIPTION "replace kOhm with Ohm in DC resistance UNITS"
REVISION "200702220000Z"
DESCRIPTION "remove DISPLAY-HINT"
REVISION "200609261000Z"
DESCRIPTION
"Removed Gr909 from fuse test result names"
REVISION "200602220135Z"
DESCRIPTION
"Initial version."
::= { occamGenericMonitorModules 3 }
-- TEXTUAL-CONVENTIONS --
MltTestType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A selection value for requesting or forcing a test.
A requested test will only run if the port is not in use.
A forced test will immediately shut the port and run the test."
SYNTAX INTEGER { request ( 1 ) , force ( 2 ) }