All pastes #517676 Raw Edit

/dev/hda

public text v1 · immutable
#517676 ·published 2007-05-29 03:07 UTC
rendered paste body
smartctl version 5.37 [i686-mingw32-xp-sp2] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.7 and 7200.7 Plus family
Device Model:     ST3160023A
Serial Number:    5JS6GQ85
Firmware Version: 8.01
User Capacity:    160,041,885,696 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   6
ATA Standard is:  ATA/ATAPI-6 T13 1410D revision 2
Local Time is:    Mon May 28 23:05:09 2007 EST
SMART support is: Available - device has SMART capability.
                  Enabled status cached by OS, trying SMART RETURN STATUS cmd.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		 ( 430) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 111) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   055   053   006    Pre-fail  Always       -       68659408
  3 Spin_Up_Time            0x0003   097   096   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       0
  5 Reallocated_Sector_Ct   0x0033   098   098   036    Pre-fail  Always       -       86
  7 Seek_Error_Rate         0x000f   081   060   030    Pre-fail  Always       -       155676638
  9 Power_On_Hours          0x0032   087   087   000    Old_age   Always       -       12147
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       123
194 Temperature_Celsius     0x0022   054   058   000    Old_age   Always       -       54
195 Hardware_ECC_Recovered  0x001a   055   053   000    Old_age   Always       -       68659408
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       27
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       27
199 UDMA_CRC_Error_Count    0x003e   200   199   000    Old_age   Always       -       1
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline      -       0
202 TA_Increase_Count       0x0032   099   252   000    Old_age   Always       -       1

SMART Error Log Version: 1
ATA Error Count: 229 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 229 occurred at disk power-on lifetime: 12145 hours (506 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 3f 67 63 e0  Error: UNC 8 sectors at LBA = 0x0063673f = 6514495

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 3f 67 63 e0 00      06:04:07.031  READ DMA EXT
  25 00 01 00 00 00 e0 00      06:04:02.999  READ DMA EXT
  25 00 01 00 00 00 e0 00      06:04:02.921  READ DMA EXT
  25 00 01 00 00 00 e0 00      06:04:02.803  READ DMA EXT
  25 00 80 9f 2c 24 e0 00      06:04:02.803  READ DMA EXT

Error 228 occurred at disk power-on lifetime: 12145 hours (506 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 3f 67 63 e0  Error: UNC 8 sectors at LBA = 0x0063673f = 6514495

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 3f 67 63 e0 00      06:04:02.767  READ DMA EXT
  25 00 80 bf 68 63 e0 00      06:04:02.999  READ DMA EXT
  35 00 08 3f aa 61 e0 00      06:04:02.921  WRITE DMA EXT
  35 00 08 0f aa 61 e0 00      06:04:02.803  WRITE DMA EXT
  35 00 08 c7 a9 61 e0 00      06:04:02.803  WRITE DMA EXT

Error 227 occurred at disk power-on lifetime: 12145 hours (506 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 3f 67 63 e0  Error: UNC 8 sectors at LBA = 0x0063673f = 6514495

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 3f 67 63 e0 00      06:03:58.496  READ DMA EXT
  25 00 01 00 00 00 e0 00      06:03:58.496  READ DMA EXT
  25 00 01 00 00 00 e0 00      06:03:58.485  READ DMA EXT
  35 00 05 8f 5c e9 e0 00      06:03:58.484  WRITE DMA EXT
  35 00 08 37 00 5e e0 00      06:03:58.483  WRITE DMA EXT

Error 226 occurred at disk power-on lifetime: 12145 hours (506 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 3f 67 63 e0  Error: UNC 8 sectors at LBA = 0x0063673f = 6514495

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 3f 67 63 e0 00      06:03:54.385  READ DMA EXT
  25 00 01 00 00 00 e0 00      06:03:54.378  READ DMA EXT
  25 00 01 00 00 00 e0 00      06:03:54.378  READ DMA EXT
  35 00 05 8f 5c e9 e0 00      06:03:54.378  WRITE DMA EXT
  35 00 05 7f b3 ac e0 00      06:03:54.357  WRITE DMA EXT

Error 225 occurred at disk power-on lifetime: 12145 hours (506 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 80 3f 67 63 e0  Error: UNC 128 sectors at LBA = 0x0063673f = 6514495

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 80 3f 67 63 e0 00      06:03:50.122  READ DMA EXT
  25 00 80 bf 66 63 e0 00      06:03:50.120  READ DMA EXT
  25 00 80 3f 66 63 e0 00      06:03:50.119  READ DMA EXT
  25 00 08 37 65 63 e0 00      06:03:50.118  READ DMA EXT
  25 00 08 2f 65 63 e0 00      06:03:50.117  READ DMA EXT

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.