I am reinstalling Sun cluster software after upgrading the OS to Solaris 10 from Solaris 9.  I created a "/globaldevices" slice on the root disk of each node, installed Sun cluster 3.1 (latest one from Sun website).  I then ran "scinstall" to add the new nodes and when asked, I chose to configure a quorum device later.  After successfully adding the nodes, each node took turn to reboot.  After booting up, I ran this command to get the DID device for quorum device in "scsetup"

[root@comapp1]$ scdidadm -L
1        comapp2:/dev/rdsk/c0t256000C0FFC8455Bd1 /dev/did/rdsk/d1     
1        comapp2:/dev/rdsk/c1t216000C0FF88455Bd1 /dev/did/rdsk/d1     
2        comapp2:/dev/rdsk/c0t256000C0FFC8455Bd0 /dev/did/rdsk/d2     
2        comapp2:/dev/rdsk/c1t216000C0FF88455Bd0 /dev/did/rdsk/d2     
3        comapp2:/dev/rdsk/c2t0d0       /dev/did/rdsk/d3     
4        comapp2:/dev/rdsk/c3t0d0       /dev/did/rdsk/d4     
5        comapp2:/dev/rdsk/c3t1d0       /dev/did/rdsk/d5     
6        comapp2:/dev/rdsk/c3t2d0       /dev/did/rdsk/d6    

Both nodes that I run, it only showed the entries for comapp2, and nothing from comapp1.  I think it must show entries for both nodes so I can pick one for the quorum device. 

Here are some additional info:


[root@comapp1]$ scstat
------------------------------------------------------------------

-- Cluster Nodes --

                    Node name           Status
                    ---------           ------
  Cluster node:     comapp2             Online
  Cluster node:     comapp1             Online

------------------------------------------------------------------

-- Cluster Transport Paths --

                    Endpoint               Endpoint               Status
                    --------               --------               ------
  Transport path:   comapp2:ce1            comapp1:ce1            Path online
  Transport path:   comapp2:ce6            comapp1:ce6            Path online

------------------------------------------------------------------

-- Quorum Summary --

  Quorum votes possible:      1
  Quorum votes needed:        1
  Quorum votes present:       1


-- Quorum Votes by Node --

                    Node Name           Present Possible Status
                    ---------           ------- -------- ------
  Node votes:       comapp2             1        1       Online
  Node votes:       comapp1             0        0       Online


-- Quorum Votes by Device --

                    Device Name         Present Possible Status
                    -----------         ------- -------- ------

------------------------------------------------------------------


-- Device Group Servers --

                         Device Group        Primary             Secondary
                         ------------        -------             ---------


-- Device Group Status --

                              Device Group        Status              
                              ------------        ------              


-- Multi-owner Device Groups --

                              Device Group        Online Status
                              ------------        -------------

------------------------------------------------------------------
------------------------------------------------------------------

-- IPMP Groups --

              Node Name           Group   Status         Adapter   Status
              ---------           -----   ------         -------   ------
  IPMP Group: comapp1             sc_ipmp0 Online         ce3       Online
  IPMP Group: comapp1             comipmp1 Online         ce2       Standby
  IPMP Group: comapp1             comipmp1 Online         ce0       Online






[root@comapp1]$ cfgadm -o show_FCP_dev -al
Ap_Id                          Type         Receptacle   Occupant     Condition
c0                             fc-fabric    connected    configured   unknown
c0::216000c0ff88455b,0         disk         connected    configured   unknown
c0::216000c0ff88455b,1         disk         connected    configured   unknown
c0::226000c0ffa8455b,0         ESI          connected    configured   unknown
c0::256000c0ff683ce1,0         ESI          connected    configured   unknown
c0::266000c0ff883ce1,0         ESI          connected    configured   unknown
c1                             fc-fabric    connected    configured   unknown
c1::216000c0ff283ce1,0         ESI          connected    configured   unknown
c1::226000c0ff483ce1,0         ESI          connected    configured   unknown
c1::256000c0ffc8455b,0         disk         connected    configured   unknown
c1::256000c0ffc8455b,1         disk         connected    configured   unknown
c1::266000c0ffe8455b,0         ESI          connected    configured   unknown
c4                             fc           connected    unconfigured unknown
c5                             fc           connected    unconfigured unknown


[root@comapp2]$ cfgadm -o show_FCP_dev -al
Ap_Id                          Type         Receptacle   Occupant     Condition
c0                             fc-fabric    connected    configured   unknown
c0::216000c0ff283ce1,0         ESI          connected    configured   unknown
c0::226000c0ff483ce1,0         ESI          connected    configured   unknown
c0::256000c0ffc8455b,0         disk         connected    configured   unknown
c0::256000c0ffc8455b,1         disk         connected    configured   unknown
c0::266000c0ffe8455b,0         ESI          connected    configured   unknown
c1                             fc-fabric    connected    configured   unknown
c1::216000c0ff88455b,0         disk         connected    configured   unknown
c1::216000c0ff88455b,1         disk         connected    configured   unknown
c1::226000c0ffa8455b,0         ESI          connected    configured   unknown
c1::256000c0ff683ce1,0         ESI          connected    configured   unknown
c1::266000c0ff883ce1,0         ESI          connected    configured   unknown
c4                             fc           connected    unconfigured unknown
c5                             fc           connected    unconfigured unknown
[root@comapp1]$ format
Searching for disks...done


AVAILABLE DISK SELECTIONS:
       0. c0t216000C0FF88455Bd0 <SUN-StorEdge3510-411I cyl 30 alt 2 hd 64 sec 32>
          /pci@1d,700000/SUNW,qlc@2/fp@0,0/ssd@w216000c0ff88455b,0
       1. c0t216000C0FF88455Bd1 <SUN-StorEdge3510-411I cyl 50194 alt 2 hd 64 sec 255>
          /pci@1d,700000/SUNW,qlc@2/fp@0,0/ssd@w216000c0ff88455b,1
       2. c1t256000C0FFC8455Bd0 <SUN-StorEdge3510-411I cyl 30 alt 2 hd 64 sec 32>
          /pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w256000c0ffc8455b,0
       3. c1t256000C0FFC8455Bd1 <SUN-StorEdge3510-411I cyl 50194 alt 2 hd 64 sec 255>
          /pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w256000c0ffc8455b,1
       4. c3t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@1f,700000/scsi@2/sd@0,0
       5. c3t1d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@1f,700000/scsi@2/sd@1,0
       6. c3t2d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@1f,700000/scsi@2/sd@2,0

[root@comapp2]$ format
Searching for disks...done


AVAILABLE DISK SELECTIONS:
       0. c0t256000C0FFC8455Bd0 <SUN-StorEdge3510-411I cyl 30 alt 2 hd 64 sec 32>
          /pci@1d,700000/SUNW,qlc@2/fp@0,0/ssd@w256000c0ffc8455b,0
       1. c0t256000C0FFC8455Bd1 <SUN-StorEdge3510-411I cyl 50194 alt 2 hd 64 sec 255>
          /pci@1d,700000/SUNW,qlc@2/fp@0,0/ssd@w256000c0ffc8455b,1
       2. c1t216000C0FF88455Bd0 <SUN-StorEdge3510-411I cyl 30 alt 2 hd 64 sec 32>
          /pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w216000c0ff88455b,0
       3. c1t216000C0FF88455Bd1 <SUN-StorEdge3510-411I cyl 50194 alt 2 hd 64 sec 255>
          /pci@1e,600000/SUNW,qlc@3/fp@0,0/ssd@w216000c0ff88455b,1
       4. c3t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@1f,700000/scsi@2/sd@0,0
       5. c3t1d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@1f,700000/scsi@2/sd@1,0
       6. c3t2d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
          /pci@1f,700000/scsi@2/sd@2,0

Note:
The slice (0) has 30MB capacity, slice (1) has 390GB, slice (2) has 30MB and slice (3) has 390GB.  I was planning on using either slice 0 or 2 for quorum device.


[root@comapp1]$ df -kh
Filesystem             size   used  avail capacity  Mounted on
/dev/md/dsk/d0         103G   7.0G    95G     7%    /
/devices                 0K     0K     0K     0%    /devices
ctfs                     0K     0K     0K     0%    /system/contract
proc                     0K     0K     0K     0%    /proc
mnttab                   0K     0K     0K     0%    /etc/mnttab
swap                    59G   1.2M    59G     1%    /etc/svc/volatile
objfs                    0K     0K     0K     0%    /system/object
fd                       0K     0K     0K     0%    /dev/fd
swap                    59G   384K    59G     1%    /tmp
swap                    59G   112K    59G     1%    /var/run
/dev/md/dsk/d2         485M   3.6M   433M     1%    /global/.devices/node@2


[root@comapp2]$ df -kh
Filesystem             size   used  avail capacity  Mounted on
/dev/md/dsk/d0         103G   7.0G    95G     7%    /
/devices                 0K     0K     0K     0%    /devices
ctfs                     0K     0K     0K     0%    /system/contract
proc                     0K     0K     0K     0%    /proc
mnttab                   0K     0K     0K     0%    /etc/mnttab
swap                    58G   1.2M    58G     1%    /etc/svc/volatile
objfs                    0K     0K     0K     0%    /system/object
fd                       0K     0K     0K     0%    /dev/fd
swap                    58G    32K    58G     1%    /tmp
swap                    58G    40K    58G     1%    /var/run
/dev/md/dsk/d2         485M   3.6M   433M     1%    /global/.devices/node@2