All pastes #457823 Raw Edit

Miscellany

public text v1 · immutable
#457823 ·published 2007-04-25 16:04 UTC
rendered paste body
smartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     ST3802110A
Serial Number:    5LRB2JLM
Firmware Version: 3.AAJ
User Capacity:    80,026,361,856 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Wed Apr 25 18:03:58 2007 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 ( 430) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  27) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   071   071   006    Pre-fail  Always       -       0
  3 Spin_Up_Time            0x0003   095   094   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       11
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   077   066   030    Pre-fail  Always       -       56380512
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       -       1530
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       16
187 Unknown_Attribute       0x0032   032   032   000    Old_age   Always       -       68
189 Unknown_Attribute       0x003a   098   098   000    Old_age   Always       -       2
190 Unknown_Attribute       0x0022   069   059   045    Old_age   Always       -       555286559
194 Temperature_Celsius     0x0022   031   041   000    Old_age   Always       -       31 (Lifetime Min/Max 0/19)
195 Hardware_ECC_Recovered  0x001a   046   045   000    Old_age   Always       -       46655164
197 Current_Pending_Sector  0x0012   097   097   000    Old_age   Always       -       67
198 Offline_Uncorrectable   0x0010   097   097   000    Old_age   Offline      -       67
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline      -       0
202 TA_Increase_Count       0x0032   100   253   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 68 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 68 occurred at disk power-on lifetime: 1436 hours (59 days + 20 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 5d fe c5 e0  Error: UNC at LBA = 0x00c5fe5d = 12975709

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 57 fe c5 e0 00      06:08:50.979  READ DMA EXT
  35 00 10 7f 00 18 e0 00      06:08:50.978  WRITE DMA EXT
  35 00 28 4f 00 18 e0 00      06:08:50.978  WRITE DMA EXT
  35 00 08 4f 00 90 e0 00      06:08:50.978  WRITE DMA EXT
  35 00 20 4f 00 b0 e0 00      06:08:50.978  WRITE DMA EXT

Error 67 occurred at disk power-on lifetime: 1436 hours (59 days + 20 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 5d fe c5 e0  Error: UNC at LBA = 0x00c5fe5d = 12975709

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 57 fe c5 e0 00      06:08:40.157  READ DMA EXT
  25 00 08 4f fe c5 e0 00      06:08:40.149  READ DMA EXT
  25 00 08 47 fe c5 e0 00      06:08:40.146  READ DMA EXT
  25 00 08 3f fe c5 e0 00      06:08:48.856  READ DMA EXT
  25 00 08 d7 86 ad e0 00      06:08:48.856  READ DMA EXT

Error 66 occurred at disk power-on lifetime: 1436 hours (59 days + 20 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 5d fe c5 e0  Error: UNC at LBA = 0x00c5fe5d = 12975709

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 50 57 fe c5 e0 00      06:08:40.157  READ DMA EXT
  25 00 58 4f fe c5 e0 00      06:08:40.149  READ DMA EXT
  25 00 60 47 fe c5 e0 00      06:08:40.146  READ DMA EXT
  25 00 68 3f fe c5 e0 00      06:08:40.135  READ DMA EXT
  25 00 98 27 e5 c5 e0 00      06:08:40.135  READ DMA EXT

Error 65 occurred at disk power-on lifetime: 1436 hours (59 days + 20 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 5d fe c5 e0  Error: UNC at LBA = 0x00c5fe5d = 12975709

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 58 4f fe c5 e0 00      06:08:40.157  READ DMA EXT
  25 00 60 47 fe c5 e0 00      06:08:40.149  READ DMA EXT
  25 00 68 3f fe c5 e0 00      06:08:40.146  READ DMA EXT
  25 00 98 27 e5 c5 e0 00      06:08:40.135  READ DMA EXT
  25 00 00 27 e4 c5 e0 00      06:08:40.135  READ DMA EXT

Error 64 occurred at disk power-on lifetime: 1436 hours (59 days + 20 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 5d fe c5 e0  Error: UNC at LBA = 0x00c5fe5d = 12975709

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 60 47 fe c5 e0 00      06:08:40.157  READ DMA EXT
  25 00 68 3f fe c5 e0 00      06:08:40.149  READ DMA EXT
  25 00 98 27 e5 c5 e0 00      06:08:40.146  READ DMA EXT
  25 00 00 27 e4 c5 e0 00      06:08:40.135  READ DMA EXT
  25 00 00 27 e3 c5 e0 00      06:08:40.135  READ DMA EXT

SMART Self-test log structure revision number 1

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.