All pastes #446974 Raw Edit

Xgates

public text v1 · immutable
·published 2007-04-18 19:24 UTC
rendered paste body
el:     Maxtor 7L300S0
Serial Number:    L611HP0H
Firmware Version: BANC1G10
User Capacity:    300,090,728,448 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 0
Local Time is:    Wed Apr 18 09:23:04 2007 HST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (2283) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 118) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  3 Spin_Up_Time            0x0027   181   180   063    Pre-fail  Always       -       22690
  4 Start_Stop_Count        0x0032   253   253   000    Old_age   Always       -       626
  5 Reallocated_Sector_Ct   0x0033   253   253   063    Pre-fail  Always       -       0
  6 Read_Channel_Margin     0x0001   253   253   100    Pre-fail  Offline      -       0
  7 Seek_Error_Rate         0x000a   253   252   000    Old_age   Always       -       0
  8 Seek_Time_Performance   0x0027   250   242   187    Pre-fail  Always       -       51425
  9 Power_On_Hours          0x0032   238   238   000    Old_age   Always       -       63661
 10 Spin_Retry_Count        0x002b   253   252   157    Pre-fail  Always       -       0
 11 Calibration_Retry_Count 0x002b   253   252   223    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   252   252   000    Old_age   Always       -       726
192 Power-Off_Retract_Count 0x0032   253   253   000    Old_age   Always       -       0
193 Load_Cycle_Count        0x0032   253   253   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0032   036   253   000    Old_age   Always       -       34
195 Hardware_ECC_Recovered  0x000a   253   252   000    Old_age   Always       -       2150
196 Reallocated_Event_Count 0x0008   253   253   000    Old_age   Offline      -       0
197 Current_Pending_Sector  0x0008   253   253   000    Old_age   Offline      -       0
198 Offline_Uncorrectable   0x0008   253   253   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0008   003   001   000    Old_age   Offline      -       329
200 Multi_Zone_Error_Rate   0x000a   253   252   000    Old_age   Always       -       0
201 Soft_Read_Error_Rate    0x000a   253   252   000    Old_age   Always       -       0
202 TA_Increase_Count       0x000a   253   252   000    Old_age   Always       -       0
203 Run_Out_Cancel          0x000b   253   252   180    Pre-fail  Always       -       0
204 Shock_Count_Write_Opern 0x000a   253   252   000    Old_age   Always       -       0
205 Shock_Rate_Write_Opern  0x000a   253   252   000    Old_age   Always       -       0
207 Spin_High_Current       0x002a   253   252   000    Old_age   Always       -       0
208 Spin_Buzz               0x002a   253   252   000    Old_age   Always       -       0
209 Offline_Seek_Performnce 0x0024   241   241   000    Old_age   Offline      -       150
210 Unknown_Attribute       0x0032   253   252   000    Old_age   Always       -       0
211 Unknown_Attribute       0x0032   253   252   000    Old_age   Always       -       0
212 Unknown_Attribute       0x0032   253   252   000    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.