All pastes #42713 Raw Edit

Stuff

public text v1 · immutable
#42713 ·published 2006-02-22 00:07 UTC
rendered paste body
mdione@luxury:~$ sudo smartctl -a /dev/hdb
smartctl version 5.32 Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD600AB-00BVA0
Serial Number:    WD-WMA7E1062591
Firmware Version: 21.01H21
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   5
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Tue Feb 21 21:06:01 2006 ART
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84) Offline data collection activity
                                        was suspended by an interrupting command from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 (3168) seconds.
Offline data collection
capabilities:                    (0x3b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  56) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   195   174   051    Pre-fail  Always       -       164
  3 Spin_Up_Time            0x0007   121   109   021    Pre-fail  Always       -       3041
  4 Start_Stop_Count        0x0032   100   100   040    Old_age   Always       -       450
  5 Reallocated_Sector_Ct   0x0032   199   199   112    Old_age   Always       -       2
  7 Seek_Error_Rate         0x000b   200   200   051    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0032   054   054   000    Old_age   Always       -       33959
 10 Spin_Retry_Count        0x0013   100   100   051    Pre-fail  Always       -       0
 11 Calibration_Retry_Count 0x0013   100   100   051    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       447
196 Reallocated_Event_Count 0x0032   198   198   000    Old_age   Always       -       2
197 Current_Pending_Sector  0x0012   200   199   000    Old_age   Always       -       2
198 Offline_Uncorrectable   0x0012   200   199   000    Old_age   Always       -       0
199 UDMA_CRC_Error_Count    0x000a   200   253   000    Old_age   Always       -       109
200 Multi_Zone_Error_Rate   0x0009   181   126   051    Pre-fail  Offline      -       232

SMART Error Log Version: 1
ATA Error Count: 59 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 59 occurred at disk power-on lifetime: 118 hours (4 days + 22 hours)
  When the command that caused the error occurred, the device was doing SMART Offline or Self-test.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 02 07 06 00 e0  Error: UNC 2 sectors at LBA = 0x00000607 = 1543

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 02 06 06 00 e0 00      00:53:31.150  READ DMA
  c8 00 04 04 06 00 e0 00      00:53:25.850  READ DMA
  c8 00 06 02 06 00 e0 00      00:53:20.750  READ DMA
  c8 00 08 00 06 00 e0 00      00:53:15.500  READ DMA
  c8 00 80 80 07 00 e0 00      00:53:15.450  READ DMA

Error 58 occurred at disk power-on lifetime: 118 hours (4 days + 22 hours)
  When the command that caused the error occurred, the device was doing SMART Offline or Self-test.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 04 05 06 00 e0  Error: UNC 4 sectors at LBA = 0x00000605 = 1541

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 04 04 06 00 e0 00      00:53:25.850  READ DMA
  c8 00 06 02 06 00 e0 00      00:53:20.750  READ DMA
  c8 00 08 00 06 00 e0 00      00:53:15.500  READ DMA
  c8 00 80 80 07 00 e0 00      00:53:15.450  READ DMA
  c8 00 80 00 07 00 e0 00      00:53:15.450  READ DMA

Error 57 occurred at disk power-on lifetime: 118 hours (4 days + 22 hours)
  When the command that caused the error occurred, the device was doing SMART Offline or Self-test.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 06 05 06 00 e0  Error: UNC 6 sectors at LBA = 0x00000605 = 1541

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 06 02 06 00 e0 00      00:53:20.750  READ DMA
  c8 00 08 00 06 00 e0 00      00:53:15.500  READ DMA
  c8 00 80 80 07 00 e0 00      00:53:15.450  READ DMA
  c8 00 80 00 07 00 e0 00      00:53:15.450  READ DMA
  c8 00 02 06 06 00 e0 00      00:53:07.300  READ DMA

Error 56 occurred at disk power-on lifetime: 118 hours (4 days + 22 hours)
  When the command that caused the error occurred, the device was doing SMART Offline or Self-test.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 05 06 00 e0  Error: UNC 8 sectors at LBA = 0x00000605 = 1541

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 08 00 06 00 e0 00      00:53:15.500  READ DMA
  c8 00 80 80 07 00 e0 00      00:53:15.450  READ DMA
  c8 00 80 00 07 00 e0 00      00:53:15.450  READ DMA
  c8 00 02 06 06 00 e0 00      00:53:07.300  READ DMA
  c8 00 04 04 06 00 e0 00      00:53:02.050  READ DMA

Error 55 occurred at disk power-on lifetime: 118 hours (4 days + 22 hours)
  When the command that caused the error occurred, the device was doing SMART Offline or Self-test.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 02 07 06 00 e0  Error: UNC 2 sectors at LBA = 0x00000607 = 1543

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 02 06 06 00 e0 00      00:53:07.300  READ DMA
  c8 00 04 04 06 00 e0 00      00:53:02.050  READ DMA
  c8 00 06 02 06 00 e0 00      00:52:56.800  READ DMA
  c8 00 08 00 06 00 e0 00      00:52:51.550  READ DMA
  c8 00 80 80 06 00 e0 00      00:52:51.550  READ DMA

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Conveyance offline  Completed without error       00%       119         -

Device does not support Selective Self Tests/Logging