rendered paste bodysmartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Model Family: HITACHI Travelstar DK23XX/DK23XXB series
Device Model: HITACHI_DK23EA-40B
Serial Number: FT4378
Firmware Version: 00K3A0B6
User Capacity: 40,007,761,920 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 3
Local Time is: Sat Feb 10 10:55:16 2007 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 248) Self-test routine in progress...
80% of test remaining.
Total time to complete Offline
data collection: (2020) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 34) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000d 100 100 050 Pre-fail Offline - 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 3930
3 Spin_Up_Time 0x0007 100 100 050 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 1268
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 3
7 Seek_Error_Rate 0x000f 100 100 050 Pre-fail Always - 343
8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 1228
9 Power_On_Minutes 0x0032 085 085 000 Old_age Always - 7988h+00m
10 Spin_Retry_Count 0x0013 100 100 050 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 1258
191 G-Sense_Error_Rate 0x000a 100 099 000 Old_age Always - 646
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 52
193 Load_Cycle_Count 0x0032 045 045 000 Old_age Always - 332017/331964
194 Temperature_Celsius 0x0022 070 054 000 Old_age Always - 55 (Lifetime Min/Max 13/63)
195 Hardware_ECC_Recovered 0x001a 100 070 000 Old_age Always - 24
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 3
197 Current_Pending_Sector 0x0032 100 099 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0012 100 100 000 Old_age Always - 0
201 Soft_Read_Error_Rate 0x0012 100 100 000 Old_age Always - 0
223 Load_Retry_Count 0x0012 100 100 000 Old_age Always - 0
230 Head_Amplitude 0x0032 088 088 000 Old_age Always - 383865
250 Read_Error_Retry_Rate 0x000a 100 001 000 Old_age Always - 76
SMART Error Log Version: 1
ATA Error Count: 118 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 118 occurred at disk power-on lifetime: 3603 hours (150 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 07 78 45 da e0 Error: UNC 7 sectors at LBA = 0x00da4578 = 14304632
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 77 45 da e0 00 00:30:26.720 READ DMA
ca 00 08 af 4e 60 e0 00 00:30:26.710 WRITE DMA
c8 00 08 b9 a0 da e0 00 00:30:26.620 READ DMA
ca 00 07 5f e2 d7 e0 00 00:30:26.620 WRITE DMA
ca 00 80 77 27 88 e0 00 00:30:26.620 WRITE DMA
Error 117 occurred at disk power-on lifetime: 3603 hours (150 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 07 78 45 da e0 Error: AMNF 7 sectors at LBA = 0x00da4578 = 14304632
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 77 45 da e0 00 00:30:24.660 READ DMA
c8 00 06 5f e2 d7 e0 00 00:30:24.650 READ DMA
c8 00 20 bc 82 db e0 00 00:30:24.640 READ DMA
c8 00 40 39 82 db e0 00 00:30:24.640 READ DMA
c8 00 18 f9 7f db e0 00 00:30:24.640 READ DMA
Error 116 occurred at disk power-on lifetime: 3603 hours (150 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 07 78 45 da e0 Error: AMNF 7 sectors at LBA = 0x00da4578 = 14304632
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 77 45 da e0 00 00:30:22.510 READ DMA
c8 00 10 31 da e7 e0 00 00:30:22.430 READ DMA
c8 00 08 a7 66 de e0 00 00:30:22.430 READ DMA
c8 00 20 87 66 de e0 00 00:30:22.430 READ DMA
c8 00 20 67 66 de e0 00 00:30:22.430 READ DMA
Error 115 occurred at disk power-on lifetime: 3603 hours (150 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 07 78 45 da e0 Error: AMNF 7 sectors at LBA = 0x00da4578 = 14304632
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 d8 08 77 45 da e0 00 00:30:14.120 READ DMA
ca d8 08 af 4e 60 e0 00 00:30:14.120 WRITE DMA
c8 d8 01 00 00 00 e0 00 00:30:14.040 READ DMA
ca d8 08 9f 29 62 e0 00 00:30:14.040 WRITE DMA
ca d8 08 cf 56 60 e0 00 00:30:14.040 WRITE DMA
Error 114 occurred at disk power-on lifetime: 3603 hours (150 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 07 78 45 da e0 Error: AMNF 7 sectors at LBA = 0x00da4578 = 14304632
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 d8 08 77 45 da e0 00 00:30:12.090 READ DMA
ca d8 08 5f 29 62 e0 00 00:30:12.090 WRITE DMA
c8 d8 17 2f 2b 46 e0 00 00:30:12.080 READ DMA
c8 d8 02 f7 3b 40 e0 00 00:30:12.060 READ DMA
c8 d8 12 bf 02 40 e0 00 00:30:12.040 READ DMA
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Self-test routine in progress 80% 7988 -
# 2 Extended offline Completed without error 00% 7597 -
# 3 Short offline Completed without error 00% 7596 -
# 4 Short offline Completed without error 00% 6076 -
Device does not support Selective Self Tests/Logging