All pastes #342674 Raw Edit

Untitled

public text v1 · immutable
·published 2007-02-06 13:56 UTC
rendered paste body



haaaallo :o)







nicole@T3M4:~$ sudo smartctl -a /dev/hdc
smartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Maxtor DiamondMax Plus D740X family
Device Model:     MAXTOR 6L080L4
Serial Number:    664216713010
Firmware Version: A93.0500
User Capacity:    80.054.059.008 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   5
ATA Standard is:  ATA/ATAPI-5 T13 1321D revision 1
Local Time is:    Tue Feb  6 14:54:15 2007 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (  34) seconds.
Offline data collection
capabilities:                    (0x1b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  40) minutes.

SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0029   100   253   020    Pre-fail  Offline      -       0
  3 Spin_Up_Time            0x0027   063   062   020    Pre-fail  Always       -       4732
  4 Start_Stop_Count        0x0032   095   095   008    Old_age   Always       -       3389
  5 Reallocated_Sector_Ct   0x0033   098   036   020    Pre-fail  Always       -       14
  7 Seek_Error_Rate         0x000b   100   001   023    Pre-fail  Always   In_the_past 0
  9 Power_On_Hours          0x0012   090   090   001    Old_age   Always       -       7110
 10 Spin_Retry_Count        0x0026   100   100   000    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0013   100   100   020    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   096   096   008    Old_age   Always       -       3266
 13 Read_Soft_Error_Rate    0x000b   100   093   023    Pre-fail  Always       -       0
194 Temperature_Celsius     0x0022   079   073   042    Old_age   Always       -       56
195 Hardware_ECC_Recovered  0x001a   100   001   000    Old_age   Always       -       33689657
196 Reallocated_Event_Count 0x0010   100   253   020    Old_age   Offline      -       0
197 Current_Pending_Sector  0x0032   100   037   020    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   253   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x001a   001   001   000    Old_age   Always       -       19235

SMART Error Log Version: 1
ATA Error Count: 2198 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 2198 occurred at disk power-on lifetime: 4563 hours (190 days + 3 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 d1 18 64 f8 49 e2  Error: UNC 24 sectors at LBA = 0x0249f864 = 38402148

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 02 18 64 f8 49 e2 49      00:01:29.410  READ DMA
  c8 00 39 c9 8e 96 e0 96      00:01:29.400  READ DMA
  c8 00 50 ff c0 94 e0 94      00:01:29.394  READ DMA
  ca 00 08 8f 49 90 e0 90      00:01:29.393  WRITE DMA
  ca 00 08 17 ac 7c e0 7c      00:01:29.393  WRITE DMA

Error 2197 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 d1 01 e3 c6 04 f0  Error: UNC at LBA = 0x0004c6e3 = 313059

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  40 00 01 e3 c6 04 f0 04      00:02:03.389  READ VERIFY SECTOR(S)
  40 00 02 e5 c6 04 f0 04      00:02:03.371  READ VERIFY SECTOR(S)
  c8 00 01 00 00 00 f0 00      00:02:03.371  READ DMA
  40 00 02 e3 c6 04 f0 04      00:01:58.363  READ VERIFY SECTOR(S)
  c8 00 01 00 00 00 f0 00      00:01:58.362  READ DMA

Error 2196 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 d1 02 e3 c6 04 f0  Error: UNC at LBA = 0x0004c6e3 = 313059

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  40 00 02 e3 c6 04 f0 04      00:01:58.363  READ VERIFY SECTOR(S)
  c8 00 01 00 00 00 f0 00      00:01:58.362  READ DMA
  40 00 04 e3 c6 04 f0 04      00:01:53.352  READ VERIFY SECTOR(S)
  40 00 04 df c6 04 f0 04      00:01:53.352  READ VERIFY SECTOR(S)
  c8 00 01 3d 26 9c f0 9c      00:01:53.241  READ DMA

Error 2195 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 d1 04 e3 c6 04 f0  Error: UNC at LBA = 0x0004c6e3 = 313059

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  40 00 04 e3 c6 04 f0 04      00:01:53.352  READ VERIFY SECTOR(S)
  40 00 04 df c6 04 f0 04      00:01:53.352  READ VERIFY SECTOR(S)
  c8 00 01 3d 26 9c f0 9c      00:01:53.241  READ DMA
  40 00 08 e7 c6 04 f0 04      00:01:53.196  READ VERIFY SECTOR(S)
  c8 00 01 00 00 00 f0 00      00:01:53.196  READ DMA

Error 2194 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours)
  When the command that caused the error occurred, the device was in an unknown state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 d1 04 e3 c6 04 f0  Error: UNC at LBA = 0x0004c6e3 = 313059

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  40 00 08 df c6 04 f0 04      00:01:48.189  READ VERIFY SECTOR(S)
  40 00 10 ef c6 04 f0 04      00:01:48.175  READ VERIFY SECTOR(S)
  c8 00 01 00 00 00 f0 00      00:01:48.171  READ DMA
  40 00 10 df c6 04 f0 04      00:01:43.155  READ VERIFY SECTOR(S)
  c8 00 01 00 00 00 f0 00      00:01:43.154  READ DMA

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


Device does not support Selective Self Tests/Logging