rendered paste body
haaaallo :o)
nicole@T3M4:~$ sudo smartctl -a /dev/hdc
smartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Model Family: Maxtor DiamondMax Plus D740X family
Device Model: MAXTOR 6L080L4
Serial Number: 664216713010
Firmware Version: A93.0500
User Capacity: 80.054.059.008 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
Local Time is: Tue Feb 6 14:54:15 2007 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 34) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 40) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail Offline - 0
3 Spin_Up_Time 0x0027 063 062 020 Pre-fail Always - 4732
4 Start_Stop_Count 0x0032 095 095 008 Old_age Always - 3389
5 Reallocated_Sector_Ct 0x0033 098 036 020 Pre-fail Always - 14
7 Seek_Error_Rate 0x000b 100 001 023 Pre-fail Always In_the_past 0
9 Power_On_Hours 0x0012 090 090 001 Old_age Always - 7110
10 Spin_Retry_Count 0x0026 100 100 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 096 096 008 Old_age Always - 3266
13 Read_Soft_Error_Rate 0x000b 100 093 023 Pre-fail Always - 0
194 Temperature_Celsius 0x0022 079 073 042 Old_age Always - 56
195 Hardware_ECC_Recovered 0x001a 100 001 000 Old_age Always - 33689657
196 Reallocated_Event_Count 0x0010 100 253 020 Old_age Offline - 0
197 Current_Pending_Sector 0x0032 100 037 020 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x001a 001 001 000 Old_age Always - 19235
SMART Error Log Version: 1
ATA Error Count: 2198 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2198 occurred at disk power-on lifetime: 4563 hours (190 days + 3 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 d1 18 64 f8 49 e2 Error: UNC 24 sectors at LBA = 0x0249f864 = 38402148
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 02 18 64 f8 49 e2 49 00:01:29.410 READ DMA
c8 00 39 c9 8e 96 e0 96 00:01:29.400 READ DMA
c8 00 50 ff c0 94 e0 94 00:01:29.394 READ DMA
ca 00 08 8f 49 90 e0 90 00:01:29.393 WRITE DMA
ca 00 08 17 ac 7c e0 7c 00:01:29.393 WRITE DMA
Error 2197 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 d1 01 e3 c6 04 f0 Error: UNC at LBA = 0x0004c6e3 = 313059
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 01 e3 c6 04 f0 04 00:02:03.389 READ VERIFY SECTOR(S)
40 00 02 e5 c6 04 f0 04 00:02:03.371 READ VERIFY SECTOR(S)
c8 00 01 00 00 00 f0 00 00:02:03.371 READ DMA
40 00 02 e3 c6 04 f0 04 00:01:58.363 READ VERIFY SECTOR(S)
c8 00 01 00 00 00 f0 00 00:01:58.362 READ DMA
Error 2196 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 d1 02 e3 c6 04 f0 Error: UNC at LBA = 0x0004c6e3 = 313059
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 02 e3 c6 04 f0 04 00:01:58.363 READ VERIFY SECTOR(S)
c8 00 01 00 00 00 f0 00 00:01:58.362 READ DMA
40 00 04 e3 c6 04 f0 04 00:01:53.352 READ VERIFY SECTOR(S)
40 00 04 df c6 04 f0 04 00:01:53.352 READ VERIFY SECTOR(S)
c8 00 01 3d 26 9c f0 9c 00:01:53.241 READ DMA
Error 2195 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 d1 04 e3 c6 04 f0 Error: UNC at LBA = 0x0004c6e3 = 313059
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 04 e3 c6 04 f0 04 00:01:53.352 READ VERIFY SECTOR(S)
40 00 04 df c6 04 f0 04 00:01:53.352 READ VERIFY SECTOR(S)
c8 00 01 3d 26 9c f0 9c 00:01:53.241 READ DMA
40 00 08 e7 c6 04 f0 04 00:01:53.196 READ VERIFY SECTOR(S)
c8 00 01 00 00 00 f0 00 00:01:53.196 READ DMA
Error 2194 occurred at disk power-on lifetime: 4134 hours (172 days + 6 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 d1 04 e3 c6 04 f0 Error: UNC at LBA = 0x0004c6e3 = 313059
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 08 df c6 04 f0 04 00:01:48.189 READ VERIFY SECTOR(S)
40 00 10 ef c6 04 f0 04 00:01:48.175 READ VERIFY SECTOR(S)
c8 00 01 00 00 00 f0 00 00:01:48.171 READ DMA
40 00 10 df c6 04 f0 04 00:01:43.155 READ VERIFY SECTOR(S)
c8 00 01 00 00 00 f0 00 00:01:43.154 READ DMA
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Device does not support Selective Self Tests/Logging