rendered paste bodyMicrosoft Windows XP [Version 5.1.2600]
(C) Copyright 1985-2001 Microsoft Corp.
C:\Documents and Settings\Tomoko>smartctl -a /dev/hdb
smartctl version 5.36 [i686-mingw32-xp] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Model Family: Maxtor DiamondMax Plus 8 family
Device Model: Maxtor 6E040L0
Serial Number: E1HXAJDE
Firmware Version: NAR61590
User Capacity: 41,110,142,976 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: ATA/ATAPI-7 T13 1532D revision 0
Local Time is: Tue Dec 05 23:09:47 2006 GMTST
SMART support is: Available - device has SMART capability.
Enabled status cached by OS, trying SMART RETURN STATUS cmd.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x85) Offline data collection activity
was aborted by an interrupting command f
rom host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (1021) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off supp
ort.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 17) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
FAILED RAW_VALUE
3 Spin_Up_Time 0x0027 225 219 063 Pre-fail Always -
11059
4 Start_Stop_Count 0x0032 253 253 000 Old_age Always -
643
5 Reallocated_Sector_Ct 0x0033 020 001 063 Pre-fail Always FAILI
NG_NOW 1177
6 Read_Channel_Margin 0x0001 253 253 100 Pre-fail Offline -
0
7 Seek_Error_Rate 0x000a 253 252 000 Old_age Always -
0
8 Seek_Time_Performance 0x0027 253 244 187 Pre-fail Always -
58121
9 Power_On_Minutes 0x0032 197 197 000 Old_age Always -
986h+23m
10 Spin_Retry_Count 0x002b 251 250 157 Pre-fail Always -
2
11 Calibration_Retry_Count 0x002b 253 252 223 Pre-fail Always -
0
12 Power_Cycle_Count 0x0032 252 252 000 Old_age Always -
668
192 Power-Off_Retract_Count 0x0032 253 253 000 Old_age Always -
497
193 Load_Cycle_Count 0x0032 253 253 000 Old_age Always -
2474
194 Temperature_Celsius 0x0032 253 253 000 Old_age Always -
42
195 Hardware_ECC_Recovered 0x000a 249 246 000 Old_age Always -
46611
196 Reallocated_Event_Count 0x0008 001 001 000 Old_age Offline -
4515
197 Current_Pending_Sector 0x0008 023 001 000 Old_age Offline -
1164
198 Offline_Uncorrectable 0x0008 001 001 000 Old_age Offline -
27101
199 UDMA_CRC_Error_Count 0x0008 199 199 000 Old_age Offline -
0
200 Multi_Zone_Error_Rate 0x000a 253 252 000 Old_age Always -
0
201 Soft_Read_Error_Rate 0x000a 253 249 000 Old_age Always -
6
202 TA_Increase_Count 0x000a 001 001 000 Old_age Always -
580
203 Run_Out_Cancel 0x000b 248 001 180 Pre-fail Always In_th
e_past 3176
204 Shock_Count_Write_Opern 0x000a 246 001 000 Old_age Always -
9
205 Shock_Rate_Write_Opern 0x000a 253 252 000 Old_age Always -
0
207 Spin_High_Current 0x002a 251 250 000 Old_age Always -
2
208 Spin_Buzz 0x002a 253 252 000 Old_age Always -
0
209 Offline_Seek_Performnce 0x0024 251 181 000 Old_age Offline -
0
99 Unknown_Attribute 0x0004 253 253 000 Old_age Offline -
0
100 Unknown_Attribute 0x0004 253 253 000 Old_age Offline -
0
101 Unknown_Attribute 0x0004 253 253 000 Old_age Offline -
0
SMART Error Log Version: 1
Warning: ATA error count 60487 inconsistent with error log pointer 5
ATA Error Count: 60487 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 60487 occurred at disk power-on lifetime: 18327 hours (763 days + 15 hours
)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 65 9f e4 16 f0 Error: UNC 101 sectors at LBA = 0x0016e49f = 1500319
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 80 9f e4 16 f0 00 03:00:40.128 READ DMA
c8 00 80 1f e4 16 f0 00 03:00:40.128 READ DMA
c8 00 80 9f e3 16 f0 00 03:00:40.128 READ DMA
c8 00 80 1f e3 16 f0 00 03:00:40.112 READ DMA
c8 00 80 9f e2 16 f0 00 03:00:40.112 READ DMA
Error 60486 occurred at disk power-on lifetime: 18327 hours (763 days + 15 hours
)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 13 9f 83 05 f0 Error: UNC 19 sectors at LBA = 0x0005839f = 361375
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 80 9f 83 05 f0 00 02:56:34.896 READ DMA
c8 00 80 1f 83 05 f0 00 02:56:34.896 READ DMA
c8 00 80 9f 82 05 f0 00 02:56:34.896 READ DMA
c8 00 80 1f 82 05 f0 00 02:56:34.704 READ DMA
c8 00 80 9f 81 05 f0 00 02:56:34.704 READ DMA
Error 60485 occurred at disk power-on lifetime: 18327 hours (763 days + 15 hours
)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 6b 9f d4 02 f0 Error: UNC 107 sectors at LBA = 0x0002d49f = 185503
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 80 9f d4 02 f0 00 02:54:46.880 READ DMA
c8 00 80 1f d4 02 f0 00 02:54:46.400 READ DMA
c8 00 80 9f d3 02 f0 00 02:54:46.400 READ DMA
c8 00 80 1f d3 02 f0 00 02:54:46.384 READ DMA
c8 00 80 9f d2 02 f0 00 02:54:46.384 READ DMA
Error 60484 occurred at disk power-on lifetime: 18325 hours (763 days + 13 hours
)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 13 af d4 02 f0 Error: AMNF 19 sectors at LBA = 0x0002d4af = 185519
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 18 af d4 02 f0 00 00:25:27.104 READ DMA
c8 00 01 00 00 00 f0 00 00:25:27.072 READ DMA
c8 00 80 e7 d4 02 f0 00 00:25:26.912 READ DMA
c8 00 18 af d4 02 f0 00 00:25:25.696 READ DMA
c8 00 01 00 00 00 f0 00 00:25:25.680 READ DMA
Error 60483 occurred at disk power-on lifetime: 18325 hours (763 days + 13 hours
)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 13 af d4 02 f0 Error: AMNF 19 sectors at LBA = 0x0002d4af = 185519
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 18 af d4 02 f0 00 00:25:25.696 READ DMA
c8 00 01 00 00 00 f0 00 00:25:25.680 READ DMA
c8 00 20 c7 d4 02 f0 00 00:25:25.440 READ DMA
c8 00 10 af d4 02 f0 00 00:25:24.240 READ DMA
c8 00 28 bf d4 02 f0 00 00:25:22.864 READ DMA
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
C:\Documents and Settings\Tomoko>