;signalling=em_w
;
; All those in group 0 I'll use for outgoing calls
;
;
; For example, maybe we have some other channels
; which start out in a different context and use
; E & M signalling instead.
;
;context=remote
;sigalling=em
;channel => 15
;channel => 16
;signalling=em_w
;
; All those in group 0 I'll use for outgoing calls
; Strip most significant digit (9) before sending
;
;stripmsd=1
;callerid=asreceived
;group=0
;signalling=fxs_ls
;channel => 45
;signalling=fxo_ls
;group=1
;callerid="Joe Schmoe" <(256) 428-6131>
;channel => 25
;callerid="Megan May" <(256) 428-6132>
;channel => 26
;callerid="Suzy Queue" <(256) 428-6233>
;channel => 27
;callerid="Larry Moe" <(256) 428-6234>
;channel => 28
;
; Sample PRI (CPE) config: Specify the switchtype, the signalling as
; either pri_cpe or pri_net for CPE or Network termination, and generally
; you will want to create a single "group" for all channels of the PRI.
;
; switchtype = national
; signalling = pri_cpe
; group = 2
; channel => 1-23
;
; Used for distintive ring support for x100p.
; You can see the dringX patterns is to set any one of the dringXcontext fields
; and they will be printed on the console when an inbound call comes in.
;
;dring1=95,0,0
;dring1context=internal1
;dring2=325,95,0
;dring2context=internal2
; If no pattern is matched here is where we go.
;context=default
;channel => 1
signalling=fxo_ks
channel=1
signalling=fxo_ks
channel=2
;context=analog1
signalling=fxs_ks
callerid=asreceived
immediate=no
channel=3
group=1
;context=analog2
signalling=fxs_ks
callerid=asreceived
immediate=no
channel=4
group=1
;signalling=fxo_ks
;channel=3
;signalling=fxo_ks
;channel=4
Type :quit<Enter> to exit Vim