All pastes #2124146 Raw Edit

Mine

public text v1 · immutable
#2124146 ·published 2012-03-04 23:18 UTC
rendered paste body
elessar:~ ariela$ dispcal -v -m -gl -qh -H cinema
Setting up the instrument
Instrument Type:   ColorMunki
Serial Number:     2018587
Firmware version:  288
Chip ID:           01-adec371200001b
Version string:    'colormunki FW V1.32  Build Nr. 1303'
Calibration Ver.:  6
Production No.:    65745
Set instrument sensor to calibration position,
 and then hit any key to continue,
 or hit Esc or Q to abort:
Calibration complete
Place instrument on test window.
Hit Esc or Q to give up, any other key to continue:
Target white = native white point
Target white brightness = native brightness
Target black brightness = native brightness
Target gamma = L* curve
Commencing device calibration
patch 6 of 6
Black = XYZ   0.25   0.25   0.38
Red   = XYZ  58.19  30.33   1.58
Green = XYZ  56.90 109.62  11.07
Blue  = XYZ  29.82  11.52 161.71
White = XYZ 144.90 151.49 173.69
patch 80 of 80
Initial native brightness target = 151.494521 cd/m^2
Target white value is XYZ 144.898856 151.494521 173.693423
Adjusted target black XYZ 0.24 0.25 0.29, Lab 1.50 0.00 0.00
Target black after min adjust: XYZ 0.310 0.324 0.371, Lab 1.930 0.000 0.000
Gamma curve input offset = 0.000000, output offset = 0.002137, power = 0.000000
Total Iteration 4, Final Samples = 96 Final Repeat threshold = 0.400000
Creating initial calibration curves...
Doing iteration 1 with 12 sample points and repeat threshold of 1.131371 DE
patch 12 of 12
Brightness error = 0.000000 cd/m^2 (is 151.433926, should be 151.433926)
White point error = 0.000000 deltaE
Maximum neutral error (@ 0.283220) = 1.071289 deltaE
Average neutral error = 0.704950 deltaE
Number of measurements taken = 22
Computing update to calibration curves...
Doing iteration 2 with 24 sample points and repeat threshold of 0.800000 DE
patch 24 of 24
Brightness error = 0.000000 cd/m^2 (is 151.370769, should be 151.370769)
White point error = 0.000000 deltaE
Maximum neutral error (@ 0.353123) = 0.798558 deltaE
Average neutral error = 0.533175 deltaE
Number of measurements taken = 58
Computing update to calibration curves...
Doing iteration 3 with 48 sample points and repeat threshold of 0.565685 DE
patch 48 of 48
Brightness error = 0.000000 cd/m^2 (is 151.490443, should be 151.490443)
White point error = 0.000000 deltaE
Maximum neutral error (@ 0.144028) = 1.054379 deltaE
Average neutral error = 0.407290 deltaE
Failed to meet target 0.565685 delta E, got worst case 1.054379
Number of measurements taken = 215
Computing update to calibration curves...
Doing iteration 4 with 96 sample points and repeat threshold of 0.400000 DE
patch 96 of 96
Brightness error = 0.000000 cd/m^2 (is 151.354389, should be 151.354389)
White point error = 0.000000 deltaE
Maximum neutral error (@ 0.069836) = 1.563194 deltaE
Average neutral error = 0.415944 deltaE
Failed to meet target 0.400000 delta E, got worst case 1.369969
Number of measurements taken = 808
The instrument can be removed from the screen.
Written calibration file 'cinema.cal'

elessar:~ ariela$ targen -v -w -d3 -g 32 cinema
RGB test chart
Compostie Grey steps = 32
Full spread patches = 836
Degree of adaptation: 0.100
Adaptation weights: Device = 0.935, Perceptual = 0.065, Curvature = 0.010
Perceptual cache resolution = 11
Acceleration grid res = 10

There are 32 unique fixed points to add (35 total fixed points)
There are 801 far spread points to add
Added 833/833
After seeding points: MinPoint = 5.358, Min = 4.925, Avg. = 8.814, Max = 11.293, 0.5 secs
Re-seeding
It 1: Maxmv = 0.049761, MinPoint = 5.358, Min = 3.498, Avg. = 8.849, Max = 11.493, 0.5 secs.
Re-seeding
It 2: Maxmv = 0.046361, MinPoint = 5.358, Min = 4.925, Avg. = 8.810, Max = 11.192, 0.5 secs.
Re-seeding
It 3: Maxmv = 0.034787, MinPoint = 5.358, Min = 4.925, Avg. = 8.759, Max = 10.997, 0.5 secs.
Fixing up veronoi
It 4: Maxmv = 0.021185, MinPoint = 5.358, Min = 4.925, Avg. = 8.730, Max = 10.740, 0.3 secs.
Fixing up veronoi
It 5: Maxmv = 0.010910, MinPoint = 5.358, Min = 4.925, Avg. = 8.716, Max = 10.652, 0.3 secs.
Fixing up veronoi
It 6: Maxmv = 0.000923, MinPoint = 5.358, Min = 4.925, Avg. = 8.715, Max = 10.661, 0.2 secs.
After optimization: MinPoint = 5.358, Min = 4.925, Avg. = 8.715, Max = 10.661
Total number of patches = 836
Execution time = 2.780000 seconds

elessar:~ ariela$ dispread -v -k cinema.cal -H cinema
Number of patches = 836
Setting up the instrument
Instrument Type:   ColorMunki
Serial Number:     2018587
Firmware version:  288
Chip ID:           01-adec371200001b
Version string:    'colormunki FW V1.32  Build Nr. 1303'
Calibration Ver.:  6
Production No.:    65745
Set instrument sensor to calibration position,
 and then hit any key to continue,
 or hit Esc or Q to abort:
Calibration complete
Place instrument on test window.
Hit Esc or Q to give up, any other key to continue:
patch 836 of 836
The instrument can be removed from the screen.
Written 'cinema.ti3'

elessar:~ ariela$ colprof -v -qh -al cinema
No of test patches = 836
Estimating white point
Approximate White point XYZ = 0.956325 1.000175 1.146475, Lab = 100.006766 -1.394119 -23.183315
Creating optimised per channel curves
Initial White Point XYZ 0.956325 1.000175 1.146475, Lab 100.006766 -1.394119 -23.183315
About to optimise temporary matrix
 100%
About to optimise input curves and matrix
 100%
About to optimise output curves and matrix
 100%
About to optimise input curves and matrix again
 100%
About to optimise input, matrix and output together
 100%
About to adjust a and b output curves for white point
About to create grid position input curves
Create final clut from scattered data
***************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************************
Doing White point fine tune:
Before fine tune, rel WP = XYZ 0.964069 0.999886 0.825962, Lab 99.995592 -0.003669 -0.093407
After fine tune, rel WP = XYZ 0.964200 1.000000 0.824900, Lab 100.000000 -0.000000 -0.000000
Creating fast inverse input lookups
White point XYZ = 0.956284 1.000090 1.147966, Lab = 100.003498 -1.387242 -23.285674
Find black point
Black point XYZ = 0.002699 0.002878 0.003563, Lab = 2.599287 -0.306548 -2.245240
Display Luminance = 151.750086
Done A to B table creation
Setting up B to A table lookup
Creating B to A tables
Rev cache RAM = 1610 Mbytes
There is 1 rev cache instance with 1610 Mbytes limit
There are 2 rev cache instances with 805 Mbytes limit
100%
Done B to A tables
There is 1 rev cache instance with 1610 Mbytes limit
Profile check complete, peak err = 1.734456, avg err = 0.356211, RMS = 0.435936

profcheck log:

No of test patches = 836
Profile check complete, errors(CIEDE2000): max. = 1.029833, avg. = 0.156989, RMS = 0.193927

elessar:~ ariela$  dispcal -yl -r
Set instrument sensor to calibration position,
 and then hit any key to continue,
 or hit Esc or Q to abort:
Calibration complete

Place instrument on test window.
Hit Esc or Q to give up, any other key to continue:
Current calibration response:
Black level = 0.45 cd/m^2
White level = 162.14 cd/m^2
Aprox. gamma = 2.41
Contrast ratio = 357:1
White chromaticity coordinates 0.3088, 0.3231
White    Correlated Color Temperature = 6777K, DE 2K to locus =  3.3
White Correlated Daylight Temperature = 6778K, DE 2K to locus =  1.5
White        Visual Color Temperature = 6648K, DE 2K to locus =  3.1
White     Visual Daylight Temperature = 6839K, DE 2K to locus =  1.5
The instrument can be removed from the screen.