rendered paste bodysmartctl 5.40 2010-10-16 r3189 [x86_64-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint P80 series
Device Model: SAMSUNG SP1614N
Serial Number: 0787J1FWB13136
Firmware Version: TM100-24
User Capacity: 160,041,885,696 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: ATA/ATAPI-7 T13 1532D revision 0
Local Time is: Sun May 22 21:25:03 2011 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 249) Self-test routine in progress...
90% of test remaining.
Total time to complete Offline
data collection: (5760) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 96) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0007 081 042 000 Pre-fail Always - 3776
4 Start_Stop_Count 0x0032 096 096 000 Old_age Always - 4888
5 Reallocated_Sector_Ct 0x0033 253 253 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 253 253 051 Pre-fail Always - 0
8 Seek_Time_Performance 0x0024 253 253 000 Old_age Offline - 0
9 Power_On_Half_Minutes 0x0032 094 094 000 Old_age Always - 34972h+51m
10 Spin_Retry_Count 0x0013 253 253 049 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 098 098 000 Old_age Always - 2656
194 Temperature_Celsius 0x0022 079 043 000 Old_age Always - 53
195 Hardware_ECC_Recovered 0x000a 100 100 000 Old_age Always - 151785999
196 Reallocated_Event_Count 0x0012 253 253 000 Old_age Always - 0
197 Current_Pending_Sector 0x0033 253 253 010 Pre-fail Always - 0
198 Offline_Uncorrectable 0x0031 253 253 010 Pre-fail Offline - 0
199 UDMA_CRC_Error_Count 0x000b 100 100 051 Pre-fail Always - 0
200 Multi_Zone_Error_Rate 0x000b 100 100 051 Pre-fail Always - 0
201 Soft_Read_Error_Rate 0x000b 100 100 051 Pre-fail Always - 0
SMART Error Log Version: 1
ATA Error Count: 3
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 3 occurred at disk power-on lifetime: 34949 hours (1456 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 fe 00 00 00 40 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
ef 05 fe 00 00 00 40 00 1d+19:47:52.000 SET FEATURES [Enable APM]
ec 00 01 00 00 00 00 00 1d+19:47:48.875 IDENTIFY DEVICE
c8 00 08 20 00 00 e0 00 1d+19:47:47.438 READ DMA
c8 00 08 18 00 00 e0 00 1d+19:47:47.438 READ DMA
c8 00 08 10 00 00 e0 00 1d+19:47:47.438 READ DMA
Error 2 occurred at disk power-on lifetime: 34947 hours (1456 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 fe 00 00 00 40 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
ef 05 fe 00 00 00 40 00 1d+17:38:58.750 SET FEATURES [Enable APM]
ec 00 01 00 00 00 00 00 1d+17:38:56.250 IDENTIFY DEVICE
c8 00 08 20 00 00 e0 00 1d+17:38:54.625 READ DMA
c8 00 08 18 00 00 e0 00 1d+17:38:54.625 READ DMA
c8 00 08 10 00 00 e0 00 1d+17:38:54.625 READ DMA
Error 1 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 01 00 00 a0 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
b1 c0 00 01 00 00 a0 00 00:00:10.875 DEVICE CONFIGURATION RESTORE
80 00 01 01 00 00 a0 00 00:00:10.875 [VENDOR SPECIFIC]
ec 00 03 01 00 00 a0 00 00:00:09.813 IDENTIFY DEVICE
91 00 3f 01 00 00 af 00 00:00:09.813 INITIALIZE DEVICE PARAMETERS [OBS-6]
10 00 00 01 00 00 a0 00 00:00:09.813 RECALIBRATE [OBS-4]
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 34972 -
Device does not support Selective Self Tests/Logging