rendered paste bodyeventd.log:
--- cut
2006-10-02 01:35:37,515 DEBUG [EventHandlerPool-fiber1] EventWriter: EventWriter: DBID: 68772
2006-10-02 01:35:37,524 DEBUG [EventHandlerPool-fiber1] EventWriter: SUCCESSFULLY added uei.opennms.org/vendor/alcatel/cms/systemAlarm related data into the EVENTS table
2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventWriter: EventWriter finished for : uei.opennms.org/vendor/alcatel/cms/systemAlarm
2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: Event to be broadcasted: uei.opennms.org/vendor/alcatel/cms/systemAlarm
2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: Queued event to listener: Actiond:BroadcastEventProcessor
2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: Queued event to listener: Notifd:BroadcastEventProcessor
2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: Queued event to listener: Scriptd:BroadcastEventProcessor
2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: Queued event to listener: OpenNMS.Poller.DefaultPollContext
2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] EventIpcManagerDefaultImpl: No listener interested in event: uei.opennms.org/vendor/alcatel/cms/systemAlarm
2006-10-02 01:35:37,556 DEBUG [EventHandlerPool-fiber1] AlarmWriter: AlarmWriter: uei 'uei.opennms.org/vendor/alcatel/cms/systemAlarm' marked as 'doNotPersist' or reductionKey is null.
--- cut ---
trapd.log
--- cut
2006-10-02 01:37:03,557 DEBUG [TrapQueueProcessor] TrapQueueProcessor: Trap successfully converted and sent to eventd
2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] V2TrapInformation: V2 trap numVars or pdu length: 11
2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] V2TrapInformation: v2 trap - trapInterface: /192.168.39.180
2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] V2TrapInformation: V2 trap first varbind value: 6d 5h 29m 13s 350ms
2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] V2TrapInformation: V2 trap first varbind value is of type TIMETICKS (correct)
2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] TrapIdentity: snmpTrapOID: .1.3.6.1.4.1.2323.1.13.7.1.4.1.3
2006-10-02 01:37:05,171 DEBUG [TrapQueueProcessor] EventCreator: snmp trap [Generic=6, Specific=3, EnterpriseId=.1.3.6.1.4.1.2323.1.13.7.1.4.1]
2006-10-02 01:37:05,172 DEBUG [TrapQueueProcessor] EventConfData: Match found using key: EventKey
[
id = [.1.3.6.1.4.1.2323.1.13.7.1.4.1]
generic = [6]
specific = [3]
]
2006-10-02 01:37:05,172 DEBUG [TrapQueueProcessor] TrapQueueProcessor: Trap successfully converted and sent to eventd
--- cut ---
event.xml
--- cut ---
<event>
<mask>
<maskelement>
<mename>id</mename>
<mevalue>.1.3.6.1.4.1.2323.1.13.7.1.4.1</mevalue>
</maskelement>
<maskelement>
<mename>generic</mename>
<mevalue>6</mevalue>
</maskelement>
<maskelement>
<mename>specific</mename>
<mevalue>3</mevalue>
</maskelement>
</mask>
<uei>uei.opennms.org/vendor/alcatel/cms/systemAlarm</uei>
<event-label>ALCATEL-CMS-SYSTEM defined trap event: systemAlarm</event-label>
<descr>
<p>This notification indicates that a System error type
of alarm has occurred and some action needs to be taken to
correct this error. </p><table>
<tr><td><b>
alarmId</b></td><td>
%parm[#1]%;</td><td><p;></p></td;></tr>
<tr><td><b>
alarmSeverity</b></td><td>
%parm[#2]%;</td><td><p;>
none(0)
critical(1)
major(2)
minor(3)
informational(4)
invalid(5)
</p></td;></tr>
<tr><td><b>
alarmText</b></td><td>
%parm[#3]%;</td><td><p;></p></td;></tr>
<tr><td><b>
alarmSource</b></td><td>
%parm[#4]%;</td><td><p;></p></td;></tr>
<tr><td><b>
alarmTimestamp</b></td><td>
%parm[#5]%;</td><td><p;></p></td;></tr>
<tr><td><b>
alarmAdditionalInfo</b></td><td>
%parm[#6]%;</td><td><p;></p></td;></tr>
<tr><td><b>
alarmEventType</b></td><td>
%parm[#7]%;</td><td><p;></p></td;></tr>
<tr><td><b>
alarmInstId</b></td><td>
%parm[#8]%;</td><td><p;></p></td;></tr>
<tr><td><b>
id</b></td><td>
%parm[#9]%;</td><td><p;></p></td;></tr></table>
</descr>
<logmsg dest='logndisplay'><p>
systemAlarm trap received
alarmId=%parm[#1]%
alarmSeverity=%parm[#2]%
alarmText=%parm[#3]%
alarmSource=%parm[#4]%
alarmTimestamp=%parm[#5]%
alarmAdditionalInfo=%parm[#6]%
alarmEventType=%parm[#7]%
alarmInstId=%parm[#8]%
id=%parm[#9]%</p>
</logmsg>
<severity>Indeterminate</severity>
</event>
--- cut ---