All pastes #1877526 Raw Edit

loomsen

public shellscript v1 · immutable
#1877526 ·published 2010-06-04 22:06 UTC
rendered paste body
smartctl 5.39.1 2010-01-28 r3054 [x86_64-redhat-linux-gnu] (local build)Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net=== START OF INFORMATION SECTION ===Model Family:     SAMSUNG SpinPoint F1 DT seriesDevice Model:     SAMSUNG HD103UJSerial Number:    S13PJ1KS802838Firmware Version: 1AA01118User Capacity:    1,000,204,886,016 bytesDevice is:        In smartctl database [for details use: -P show]ATA Version is:   8ATA Standard is:  ATA-8-ACS revision 3bLocal Time is:    Sat Jun  5 00:06:24 2010 CESTSMART support is: Available - device has SMART capability.SMART support is: Enabled=== START OF READ SMART DATA SECTION ===SMART overall-health self-assessment test result: PASSEDGeneral SMART Values:Offline data collection status:  (0x00)	Offline data collection activity					was never started.					Auto Offline Data Collection: Disabled.Self-test execution status:      (   0)	The previous self-test routine completed					without error or no self-test has ever 					been run.Total time to complete Offline data collection: 		 (13626) seconds.Offline data collectioncapabilities: 			 (0x7b) SMART execute Offline immediate.					Auto Offline data collection on/off support.					Suspend Offline collection upon new					command.					Offline surface scan supported.					Self-test supported.					Conveyance Self-test supported.					Selective Self-test supported.SMART capabilities:            (0x0003)	Saves SMART data before entering					power-saving mode.					Supports SMART auto save timer.Error logging capability:        (0x01)	Error logging supported.					General Purpose Logging supported.Short self-test routine recommended polling time: 	 (   2) minutes.Extended self-test routinerecommended polling time: 	 ( 228) minutes.Conveyance self-test routinerecommended polling time: 	 (  24) minutes.SCT capabilities: 	       (0x003f)	SCT Status supported.					SCT Feature Control supported.					SCT Data Table supported.SMART Attributes Data Structure revision number: 16Vendor Specific SMART Attributes with Thresholds:ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE  1 Raw_Read_Error_Rate     0x000f   100   100   051    Pre-fail  Always       -       0  3 Spin_Up_Time            0x0007   069   069   011    Pre-fail  Always       -       10040  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       450  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0  7 Seek_Error_Rate         0x000f   253   253   051    Pre-fail  Always       -       0  8 Seek_Time_Performance   0x0025   100   100   015    Pre-fail  Offline      -       12532  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       -       4800 10 Spin_Retry_Count        0x0033   100   100   051    Pre-fail  Always       -       0 11 Calibration_Retry_Count 0x0012   100   100   000    Old_age   Always       -       0 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       176 13 Read_Soft_Error_Rate    0x000e   100   100   000    Old_age   Always       -       0183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0184 End-to-End_Error        0x0033   100   100   000    Pre-fail  Always       -       0187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       0190 Airflow_Temperature_Cel 0x0022   069   065   000    Old_age   Always       -       31 (Lifetime Min/Max 17/32)194 Temperature_Celsius     0x0022   069   064   000    Old_age   Always       -       31 (Lifetime Min/Max 17/33)195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       -       2385910196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       0197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      -       0199 UDMA_CRC_Error_Count    0x003e   100   100   000    Old_age   Always       -       0200 Multi_Zone_Error_Rate   0x000a   100   100   000    Old_age   Always       -       0201 Soft_Read_Error_Rate    0x000a   100   100   000    Old_age   Always       -       0SMART Error Log Version: 1No Errors LoggedSMART Self-test log structure revision number 1Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error# 1  Short offline       Completed without error       00%       196         -SMART Selective self-test log data structure revision number 1 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS    1        0        0  Not_testing    2        0        0  Not_testing    3        0        0  Not_testing    4        0        0  Not_testing    5        0        0  Not_testingSelective self-test flags (0x0):  After scanning selected spans, do NOT read-scan remainder of disk.If Selective self-test is pending on power-up, resume after 0 minute delay.