All pastes #184795 Raw Edit

Untitled

public text v1 · immutable
#184795 ·published 2006-09-28 09:27 UTC
rendered paste body
=== START OF INFORMATION SECTION ===
Model Family:     IBM/Hitachi Travelstar 60GH and 40GN family
Device Model:     IC25N030ATCS04-0
Serial Number:    CSH305DADGAWUB
Firmware Version: CA3OA72A
User Capacity:    30,005,821,440 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   5
ATA Standard is:  ATA/ATAPI-5 T13 1321D revision 3
Local Time is:    Thu Sep 28 02:13:35 2006 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 645) seconds.
Offline data collection
capabilities:                    (0x1b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  37) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   090   090   062    Pre-fail  Always       -       65600
  2 Throughput_Performance  0x0005   102   102   040    Pre-fail  Offline      -       6042
  3 Spin_Up_Time            0x0007   133   133   033    Pre-fail  Always       -       1
  4 Start_Stop_Count        0x0012   091   091   000    Old_age   Always       -       15481
  5 Reallocated_Sector_Ct   0x0033   045   045   005    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0005   134   134   040    Pre-fail  Offline      -       30
  9 Power_On_Hours          0x0012   077   077   000    Old_age   Always       -       10511
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       1034
191 G-Sense_Error_Rate      0x000a   097   097   000    Old_age   Always       -       196611
192 Power-Off_Retract_Count 0x0032   099   099   000    Old_age   Always       -       222
193 Load_Cycle_Count        0x0012   056   056   000    Old_age   Always       -       440029
194 Temperature_Celsius     0x0002   130   130   000    Old_age   Always       -       42 (Lifetime Min/Max 8/57)196 Reallocated_Event_Count 0x0032   054   054   000    Old_age   Always       -       1138
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       16
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 9540 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 9540 occurred at disk power-on lifetime: 10509 hours (437 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  10 51 36 7c 0b 31 e2  Error: IDNF 54 sectors at LBA = 0x02310b7c = 36768636

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 03 3f 73 0b 31 e2 00      00:00:19.000  READ DMA
  c8 03 3f 34 0b 31 e2 00      00:00:19.000  READ DMA
  c8 03 3f f5 0a 31 e2 00      00:00:19.000  READ DMA
  c8 03 3f b6 0a 31 e2 00      00:00:19.000  READ DMA
  c8 03 3f 77 0a 31 e2 00      00:00:19.000  READ DMA

Error 9539 occurred at disk power-on lifetime: 10510 hours (437 days + 22 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 b0 80 80 31 e2  Error: UNC at LBA = 0x02318080 = 36798592

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  20 00 b0 80 80 31 e2 00      00:35:38.600  READ SECTOR(S)
  10 00 3f 00 00 00 e0 00      00:35:38.600  RECALIBRATE [OBS-4]
  91 00 3f 3f ff 3f ef 00      00:35:38.600  INITIALIZE DEVICE PARAMETERS [OBS-6]
  20 00 b0 80 80 31 e2 04      00:35:38.500  READ SECTOR(S)
  20 00 b0 80 80 31 e2 00      00:35:28.500  READ SECTOR(S)

Error 9538 occurred at disk power-on lifetime: 10510 hours (437 days + 22 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  10 51 b0 80 80 31 e2  Error: IDNF at LBA = 0x02318080 = 36798592

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  20 00 b0 80 80 31 e2 00      00:35:19.300  READ SECTOR(S)
  20 00 b1 7f 80 31 e2 00      00:35:09.800  READ SECTOR(S)
  10 00 3f 00 00 00 e0 00      00:35:09.800  RECALIBRATE [OBS-4]
  91 00 3f 3f ff 3f ef 00      00:35:09.800  INITIALIZE DEVICE PARAMETERS [OBS-6]
  20 00 b1 7f 80 31 e2 04      00:35:09.700  READ SECTOR(S)

Error 9537 occurred at disk power-on lifetime: 10510 hours (437 days + 22 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 b1 7f 80 31 e2  Error: UNC at LBA = 0x0231807f = 36798591

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  20 00 b1 7f 80 31 e2 00      00:35:09.800  READ SECTOR(S)
  10 00 3f 00 00 00 e0 00      00:35:09.800  RECALIBRATE [OBS-4]
  91 00 3f 3f ff 3f ef 00      00:35:09.800  INITIALIZE DEVICE PARAMETERS [OBS-6]
  20 00 b1 7f 80 31 e2 04      00:35:09.700  READ SECTOR(S)
  20 00 b1 7f 80 31 e2 00      00:35:00.400  READ SECTOR(S)

Error 9536 occurred at disk power-on lifetime: 10510 hours (437 days + 22 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  10 51 b1 7f 80 31 e2  Error: IDNF at LBA = 0x0231807f = 36798591

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  20 00 b1 7f 80 31 e2 00      00:35:00.400  READ SECTOR(S)
  20 00 b1 7f 80 31 e2 00      00:34:51.000  READ SECTOR(S)
  10 00 3f 00 00 00 e0 00      00:34:51.000  RECALIBRATE [OBS-4]
  20 00 b1 7f 80 31 e2 00      00:34:41.600  READ SECTOR(S)
  20 00 00 30 80 31 e2 00      00:34:32.100  READ SECTOR(S)

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed: read failure       50%     10508         36768636
# 2  Short offline       Completed without error       00%         0         -