rendered paste bodysmartctl 5.40 2010-02-03 r3060 [x86_64-unknown-linux-gnu] (local build)Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net=== START OF INFORMATION SECTION ===Model Family: Seagate Barracuda 7200.8 familyDevice Model: ST3200826ASSerial Number: 3ND1N1DDFirmware Version: 3.03User Capacity: 200,049,647,616 bytesDevice is: In smartctl database [for details use: -P show]ATA Version is: 7ATA Standard is: Exact ATA specification draft version not indicatedLocal Time is: Sun Mar 14 16:05:45 2010 EDTSMART support is: Available - device has SMART capability.SMART support is: Enabled=== START OF READ SMART DATA SECTION ===SMART overall-health self-assessment test result: PASSEDGeneral SMART Values:Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled.Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run.Total time to complete Offline data collection: ( 430) seconds.Offline data collectioncapabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported.SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer.Error logging capability: (0x01) Error logging supported. General Purpose Logging supported.Short self-test routine recommended polling time: ( 1) minutes.Extended self-test routinerecommended polling time: ( 67) minutes.SMART Attributes Data Structure revision number: 10Vendor Specific SMART Attributes with Thresholds:ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 048 039 006 Pre-fail Always - 67195728 3 Spin_Up_Time 0x0003 098 098 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 40 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 089 060 030 Pre-fail Always - 848687820 9 Power_On_Hours 0x0032 064 064 000 Old_age Always - 31542 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 53194 Temperature_Celsius 0x0022 045 056 000 Old_age Always - 45 (0 22 0 0)195 Hardware_ECC_Recovered 0x001a 048 039 000 Old_age Always - 67195728197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0199 UDMA_CRC_Error_Count 0x003e 200 198 000 Old_age Always - 7200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0202 Data_Address_Mark_Errs 0x0032 100 253 000 Old_age Always - 0SMART Error Log Version: 1ATA Error Count: 5 CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX]Powered_Up_Time is measured from power on, and printed asDDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,SS=sec, and sss=millisec. It "wraps" after 49.710 days.Error 5 occurred at disk power-on lifetime: 20327 hours (846 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 bf ff 22 fb e5 Error: ICRC, ABRT 191 sectors at LBA = 0x05fb22ff = 100344575 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 00 be 22 fb e5 00 10:14:31.767 READ DMA c8 00 08 b6 22 fb e5 00 10:14:31.757 READ DMA c8 00 18 26 07 fb e5 00 10:14:31.750 READ DMA c8 00 88 c6 ff fa e5 00 10:14:31.749 READ DMA c8 00 10 ae ff fa e5 00 10:14:31.749 READ DMAError 4 occurred at disk power-on lifetime: 20327 hours (846 days + 23 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 97 9f f6 fa e5 Error: ICRC, ABRT 151 sectors at LBA = 0x05faf69f = 100333215 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 f8 3e f6 fa e5 00 10:14:30.947 READ DMA c8 00 38 06 f6 fa e5 00 10:14:30.946 READ DMA c8 00 20 8e ae ec e5 00 10:14:30.939 READ DMA c8 00 48 3e ae ec e5 00 10:14:30.933 READ DMA c8 00 30 06 ae ec e5 00 10:14:30.923 READ DMAError 3 occurred at disk power-on lifetime: 17 hours (0 days + 17 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 6f f7 a6 17 e0 Error: ICRC, ABRT 111 sectors at LBA = 0x0017a6f7 = 1550071 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 80 e6 a6 17 e0 00 00:19:53.833 READ DMA EXT 25 00 a0 46 a6 17 e0 00 00:19:53.812 READ DMA EXT 25 00 68 de a5 17 e0 00 00:19:54.156 READ DMA EXT 35 00 02 41 00 00 e0 00 00:19:54.155 WRITE DMA EXT 35 00 08 3f f5 01 e0 00 00:19:54.135 WRITE DMA EXTError 2 occurred at disk power-on lifetime: 2 hours (0 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 0f 5f b9 a2 e0 Error: ICRC, ABRT 15 sectors at LBA = 0x00a2b95f = 10664287 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 80 ee b8 a2 e0 00 01:38:52.204 READ DMA EXT 25 00 80 6e b6 a2 e0 00 01:38:52.203 READ DMA EXT 25 00 00 6e b5 a2 e0 00 01:38:52.196 READ DMA EXT 25 00 80 ee b4 a2 e0 00 01:38:52.195 READ DMA EXT 25 00 80 6e b2 a2 e0 00 01:38:52.195 READ DMA EXTError 1 occurred at disk power-on lifetime: 1 hours (0 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 ef 7f b3 79 e0 Error: ICRC, ABRT 239 sectors at LBA = 0x0079b37f = 7975807 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 00 6e b2 79 e0 00 01:35:01.589 READ DMA EXT 25 00 00 6e ae 79 e0 00 01:35:01.565 READ DMA EXT 25 00 00 6e aa 79 e0 00 01:35:01.557 READ DMA EXT 25 00 00 6e a6 79 e0 00 01:35:01.551 READ DMA EXT 25 00 00 6e a2 79 e0 00 01:35:01.670 READ DMA EXTSMART Self-test log structure revision number 1Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error# 1 Short offline Completed without error 00% 31530 -# 2 Short offline Completed without error 00% 31507 -# 3 Short offline Completed without error 00% 31484 -# 4 Short offline Completed without error 00% 31460 -# 5 Extended offline Completed without error 00% 31438 -# 6 Short offline Completed without error 00% 31436 -# 7 Short offline Completed without error 00% 31413 -# 8 Short offline Completed without error 00% 31390 -# 9 Short offline Completed without error 00% 31365 -#10 Short offline Completed without error 00% 31342 -#11 Short offline Completed without error 00% 31319 -#12 Short offline Completed without error 00% 31295 -#13 Extended offline Completed without error 00% 31273 -#14 Short offline Completed without error 00% 31271 -#15 Short offline Completed without error 00% 31248 -#16 Short offline Completed without error 00% 31224 -#17 Short offline Completed without error 00% 31201 -#18 Short offline Completed without error 00% 31176 -#19 Short offline Completed without error 00% 31153 -#20 Short offline Completed without error 00% 31130 -#21 Extended offline Completed without error 00% 31108 -SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testingSelective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk.If Selective self-test is pending on power-up, resume after 0 minute delay.