rendered paste body3750-SW-1#sh run int fas 1/0/47
Building configuration...
Current configuration : 569 bytes
!
interface FastEthernet1/0/47
description downlink to 3750-SW-2
switchport access vlan 700
switchport trunk encapsulation dot1q
switchport trunk native vlan 700
switchport trunk allowed vlan 305,400,500,550,700,900,975
switchport mode dynamic desirable
speed 10
duplex half
no mdix auto
power inline never
rmon collection stats 47 owner "root@USARLSA0NMS03 [1141600849005]"
rmon collection history 47 owner "root@USARLSA0NMS03 [1141600896352]" buckets 50 interval 30
spanning-tree portfast disable
spanning-tree bpduguard disable
spanning-tree guard loop
end
3750-SW-1#
3750-SW-1#sh int fas 1/0/47
FastEthernet1/0/47 is up, line protocol is up (connected)
Hardware is Fast Ethernet, address is 0012.80ce.2a33 (bia 0012.80ce.2a33)
Description: downlink to TG
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive set (10 sec)
Half-duplex, 10Mb/s, media type is 10/100BaseTX
input flow-control is off, output flow-control is unsupported
ARP type: ARPA, ARP Timeout 04:00:00
Last input 00:00:09, output 00:00:00, output hang never
Last clearing of "show interface" counters 02:37:53
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 10000 bits/sec, 1 packets/sec
5 minute output rate 13000 bits/sec, 6 packets/sec
43964 packets input, 19705914 bytes, 0 no buffer
Received 1949 broadcasts (0 multicast)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 1891 multicast, 0 pause input
0 input packets with dribble condition detected
91585 packets output, 18095250 bytes, 0 underruns
0 output errors, 20 collisions, 0 interface resets
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier, 0 PAUSE output
0 output buffer failures, 0 output buffers swapped out
===========================================================================
3750-SW-2#sh run int fas 1/0/47
Building configuration...
Current configuration : 407 bytes
!
interface FastEthernet1/0/47
description uplink to 3750-SW-1
switchport access vlan 700
switchport trunk encapsulation dot1q
switchport trunk native vlan 700
switchport trunk allowed vlan 305,500,550,700,900,975
switchport mode dynamic desirable
speed 10
duplex half
power inline never
spanning-tree portfast disable
spanning-tree bpduguard disable
spanning-tree guard loop
end
3750-SW-2#
3750-SW-2#sh int fas 1/0/47
FastEthernet1/0/47 is up, line protocol is up (connected)
Hardware is Fast Ethernet, address is 0012.d90a.5bb3 (bia 0012.d90a.5bb3)
Description: uplink to arlac-bk22-st62-f1/0/47
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec,
reliability 254/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive set (10 sec)
Half-duplex, 10Mb/s, media type is 10/100BaseTX
input flow-control is off, output flow-control is unsupported
ARP type: ARPA, ARP Timeout 04:00:00
Last input 00:00:00, output 00:00:01, output hang never
Last clearing of "show interface" counters 02:48:28
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 15000 bits/sec, 8 packets/sec
5 minute output rate 12000 bits/sec, 4 packets/sec
95255 packets input, 18697360 bytes, 0 no buffer
Received 48400 broadcasts (0 multicast)
0 runts, 0 giants, 0 throttles
2032 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 44066 multicast, 0 pause input
0 input packets with dribble condition detected
47095 packets output, 20579263 bytes, 0 underruns
0 output errors, 28 collisions, 0 interface resets
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier, 0 PAUSE output
0 output buffer failures, 0 output buffers swapped out
3750-SW-2#