rendered paste bodyhdb.txt 15/5/09
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.8 family
Device Model: ST3200826A
Serial Number: 3ND2DJWQ
Firmware Version: 3.03
User Capacity: 200,049,647,616 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Fri May 15 11:47:56 2009 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 67) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 053 052 006 Pre-fail Always - 13454619
3 Spin_Up_Time 0x0003 099 098 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 43
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 477947525
9 Power_On_Hours 0x0032 074 074 000 Old_age Always - 22933
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 44
194 Temperature_Celsius 0x0022 045 047 000 Old_age Always - 45 (0 15 0 0)
195 Hardware_ECC_Recovered 0x001a 053 052 000 Old_age Always - 13454619
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 196 000 Old_age Always - 236
200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0
202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 236 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 236 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 f0 00 00:22:34.262 READ DMA EXT
25 00 08 00 00 00 f0 00 00:22:33.847 READ DMA EXT
10 00 ff 00 00 00 f0 00 00:22:33.846 RECALIBRATE [OBS-4]
25 00 08 00 00 00 f0 00 00:22:33.844 READ DMA EXT
25 00 08 00 00 00 f0 00 00:22:33.844 READ DMA EXT
Error 235 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 f0 00 00:22:34.262 READ DMA EXT
10 00 ff 00 00 00 f0 00 00:22:33.847 RECALIBRATE [OBS-4]
25 00 08 00 00 00 f0 00 00:22:33.846 READ DMA EXT
25 00 08 00 00 00 f0 00 00:22:33.844 READ DMA EXT
ef 02 00 00 00 00 f0 00 00:22:33.844 SET FEATURES [Enable write cache]
Error 234 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 f0 00 00:22:34.262 READ DMA EXT
25 00 08 00 00 00 f0 00 00:22:33.847 READ DMA EXT
ef 02 00 00 00 00 f0 00 00:22:33.846 SET FEATURES [Enable write cache]
27 00 00 00 00 00 f0 00 00:22:33.844 READ NATIVE MAX ADDRESS EXT
c6 00 00 00 00 00 f0 00 00:22:33.844 SET MULTIPLE MODE
Error 233 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 f0 00 00:22:05.509 READ DMA EXT
ef 02 00 00 00 00 f0 00 00:22:33.847 SET FEATURES [Enable write cache]
27 00 00 00 00 00 f0 00 00:22:33.846 READ NATIVE MAX ADDRESS EXT
c6 00 00 00 00 00 f0 00 00:22:33.844 SET MULTIPLE MODE
10 00 ff 00 00 00 f0 00 00:22:33.844 RECALIBRATE [OBS-4]
Error 232 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 f0 00 00:00:35.850 READ DMA EXT
25 00 08 00 00 00 f0 00 00:00:34.254 READ DMA EXT
10 00 ff 00 00 00 f0 00 00:00:42.468 RECALIBRATE [OBS-4]
25 00 08 00 00 00 f0 00 00:00:42.035 READ DMA EXT
25 00 08 00 00 00 f0 00 00:00:42.035 READ DMA EXT
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
hdb.txt 23-06-09
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.8 family
Device Model: ST3200826A
Serial Number: 3ND2DJWQ
Firmware Version: 3.03
User Capacity: 200,049,647,616 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue Jun 23 14:39:46 2009 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 67) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 058 052 006 Pre-fail Always - 22053062
3 Spin_Up_Time 0x0003 099 098 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 45
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 543121377
9 Power_On_Hours 0x0032 073 073 000 Old_age Always - 23856
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 46
194 Temperature_Celsius 0x0022 043 047 000 Old_age Always - 43 (0 15 0 0)
195 Hardware_ECC_Recovered 0x001a 058 052 000 Old_age Always - 22053062
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 196 000 Old_age Always - 240
200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0
202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 240 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 240 occurred at disk power-on lifetime: 23102 hours (962 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 f0 00 00:00:35.255 READ DMA EXT
25 00 08 00 00 00 f0 00 00:00:33.695 READ DMA EXT
10 00 ff 00 00 00 f0 00 00:00:41.886 RECALIBRATE [OBS-4]
25 00 08 00 00 00 f0 00 00:00:41.453 READ DMA EXT
25 00 08 00 00 00 f0 00 00:00:41.452 READ DMA EXT
Error 239 occurred at disk power-on lifetime: 23102 hours (962 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 f0 00 00:00:35.255 READ DMA EXT
10 00 ff 00 00 00 f0 00 00:00:33.695 RECALIBRATE [OBS-4]
25 00 08 00 00 00 f0 00 00:00:23.913 READ DMA EXT
25 00 08 00 00 00 f0 00 00:00:41.453 READ DMA EXT
ef 02 00 00 00 00 f0 00 00:00:41.452 SET FEATURES [Enable write cache]
Error 238 occurred at disk power-on lifetime: 23102 hours (962 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 f0 00 00:00:35.255 READ DMA EXT
25 00 08 00 00 00 f0 00 00:00:33.695 READ DMA EXT
ef 02 00 00 00 00 f0 00 00:00:23.913 SET FEATURES [Enable write cache]
27 00 00 00 00 00 f0 00 00:00:12.146 READ NATIVE MAX ADDRESS EXT
c6 00 00 00 00 00 f0 00 00:00:12.146 SET MULTIPLE MODE
Error 237 occurred at disk power-on lifetime: 23102 hours (962 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 f0 00 00:00:35.255 READ DMA EXT
ef 02 00 00 00 00 f0 00 00:00:33.695 SET FEATURES [Enable write cache]
27 00 00 00 00 00 f0 00 00:00:23.913 READ NATIVE MAX ADDRESS EXT
c6 00 00 00 00 00 f0 00 00:00:12.146 SET MULTIPLE MODE
10 00 ff 00 00 00 f0 00 00:00:12.146 RECALIBRATE [OBS-4]
Error 236 occurred at disk power-on lifetime: 22932 hours (955 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 f0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 f0 00 00:22:34.262 READ DMA EXT
25 00 08 00 00 00 f0 00 00:22:33.847 READ DMA EXT
10 00 ff 00 00 00 f0 00 00:22:33.846 RECALIBRATE [OBS-4]
25 00 08 00 00 00 f0 00 00:22:33.844 READ DMA EXT
25 00 08 00 00 00 f0 00 00:22:33.844 READ DMA EXT
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 22944 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
hdc.txt 15-5-09
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.8 family
Device Model: ST3200826A
Serial Number: 3ND2DJ2K
Firmware Version: 3.03
User Capacity: 200,049,647,616 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Fri May 15 11:48:07 2009 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 67) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 069 048 006 Pre-fail Always - 144987126
3 Spin_Up_Time 0x0003 099 098 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 43
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 488018393
9 Power_On_Hours 0x0032 074 074 000 Old_age Always - 23001
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 44
194 Temperature_Celsius 0x0022 038 043 000 Old_age Always - 38 (0 16 0 0)
195 Hardware_ECC_Recovered 0x001a 069 048 000 Old_age Always - 144987126
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 196 000 Old_age Always - 236
200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0
202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 236 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 236 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 e0 00 00:22:36.287 READ DMA EXT
25 00 08 00 00 00 e0 00 00:22:35.855 READ DMA EXT
10 00 ff 00 00 00 e0 00 00:22:35.444 RECALIBRATE [OBS-4]
25 00 08 00 00 00 e0 00 00:22:35.444 READ DMA EXT
25 00 08 00 00 00 e0 00 00:22:35.443 READ DMA EXT
Error 235 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 e0 00 00:22:36.287 READ DMA EXT
10 00 ff 00 00 00 e0 00 00:22:35.855 RECALIBRATE [OBS-4]
25 00 08 00 00 00 e0 00 00:22:35.444 READ DMA EXT
25 00 08 00 00 00 e0 00 00:22:35.444 READ DMA EXT
ef 02 00 00 00 00 e0 00 00:22:35.443 SET FEATURES [Enable write cache]
Error 234 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 e0 00 00:22:05.295 READ DMA EXT
25 00 08 00 00 00 e0 00 00:22:35.855 READ DMA EXT
ef 02 00 00 00 00 e0 00 00:22:35.444 SET FEATURES [Enable write cache]
27 00 00 00 00 00 e0 00 00:22:35.444 READ NATIVE MAX ADDRESS EXT
c6 00 00 00 00 00 e0 00 00:22:35.443 SET MULTIPLE MODE
Error 233 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 e0 00 00:22:05.295 READ DMA EXT
ef 02 00 00 00 00 e0 00 00:22:05.289 SET FEATURES [Enable write cache]
27 00 00 00 00 00 e0 00 00:22:35.444 READ NATIVE MAX ADDRESS EXT
c6 00 00 00 00 00 e0 00 00:22:35.444 SET MULTIPLE MODE
10 00 ff 00 00 00 e0 00 00:22:35.443 RECALIBRATE [OBS-4]
Error 232 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 e0 00 00:00:39.953 READ DMA EXT
25 00 08 00 00 00 e0 00 00:00:35.912 READ DMA EXT
10 00 ff 00 00 00 e0 00 00:00:34.326 RECALIBRATE [OBS-4]
25 00 08 00 00 00 e0 00 00:00:44.450 READ DMA EXT
25 00 08 00 00 00 e0 00 00:00:44.018 READ DMA EXT
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
hdc.txt 23-06-09
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.8 family
Device Model: ST3200826A
Serial Number: 3ND2DJ2K
Firmware Version: 3.03
User Capacity: 200,049,647,616 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue Jun 23 14:55:10 2009 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 67) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 058 048 006 Pre-fail Always - 186762971
3 Spin_Up_Time 0x0003 099 098 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 45
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 553298211
9 Power_On_Hours 0x0032 073 073 000 Old_age Always - 23924
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 46
194 Temperature_Celsius 0x0022 039 043 000 Old_age Always - 39 (0 16 0 0)
195 Hardware_ECC_Recovered 0x001a 058 048 000 Old_age Always - 186762971
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 196 000 Old_age Always - 240
200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0
202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 240 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 240 occurred at disk power-on lifetime: 23169 hours (965 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 e0 00 00:00:39.246 READ DMA EXT
25 00 08 00 00 00 e0 00 00:00:35.193 READ DMA EXT
10 00 ff 00 00 00 e0 00 00:00:33.633 RECALIBRATE [OBS-4]
25 00 08 00 00 00 e0 00 00:00:43.700 READ DMA EXT
25 00 08 00 00 00 e0 00 00:00:43.268 READ DMA EXT
Error 239 occurred at disk power-on lifetime: 23169 hours (965 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 e0 00 00:00:39.246 READ DMA EXT
10 00 ff 00 00 00 e0 00 00:00:35.193 RECALIBRATE [OBS-4]
25 00 08 00 00 00 e0 00 00:00:33.633 READ DMA EXT
25 00 08 00 00 00 e0 00 00:00:23.876 READ DMA EXT
ef 02 00 00 00 00 e0 00 00:00:43.268 SET FEATURES [Enable write cache]
Error 238 occurred at disk power-on lifetime: 23169 hours (965 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 e0 00 00:00:39.246 READ DMA EXT
25 00 08 00 00 00 e0 00 00:00:35.193 READ DMA EXT
ef 02 00 00 00 00 e0 00 00:00:33.633 SET FEATURES [Enable write cache]
27 00 00 00 00 00 e0 00 00:00:23.876 READ NATIVE MAX ADDRESS EXT
c6 00 00 00 00 00 e0 00 00:00:12.208 SET MULTIPLE MODE
Error 237 occurred at disk power-on lifetime: 23169 hours (965 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 e0 00 00:00:39.246 READ DMA EXT
ef 02 00 00 00 00 e0 00 00:00:35.193 SET FEATURES [Enable write cache]
27 00 00 00 00 00 e0 00 00:00:33.633 READ NATIVE MAX ADDRESS EXT
c6 00 00 00 00 00 e0 00 00:00:23.876 SET MULTIPLE MODE
10 00 ff 00 00 00 e0 00 00:00:12.208 RECALIBRATE [OBS-4]
Error 236 occurred at disk power-on lifetime: 23000 hours (958 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 07 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000007 = 7
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 00 00 e0 00 00:22:36.287 READ DMA EXT
25 00 08 00 00 00 e0 00 00:22:35.855 READ DMA EXT
10 00 ff 00 00 00 e0 00 00:22:35.444 RECALIBRATE [OBS-4]
25 00 08 00 00 00 e0 00 00:22:35.444 READ DMA EXT
25 00 08 00 00 00 e0 00 00:22:35.443 READ DMA EXT
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 23078 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.